How to Guide
Ready to Use Grout  
Physical Properties 
TEC® Skill Set™ Ready to Use Grout 
Description 
Physical State 
Paste 
Color 
Available in 8 standard colors 
Initial Cure [at 72º (22ºC)] 
24 hours 
Final Cure 
7 days 
VOC/Liter of Material 
28 grams less water and 
exempt compounds 
Foot Traffic Rating (ASTM C627) 
Residential 
Storage 
Store in a cool, dry location. 
Do not store open containers. 
Freeze/thaw stable 
Shelf Life 
Maximum of 18 months from 
date of manufacture in 
properly stored, unopened 
package. 
5. Installation Instructions 
Surface Preparation 
Area must be clean, dry, free of dirt and dust. Grout joint should be 
free of sealers. 
Application 
1.  Grout no more than 10 sq. ft. at a time. 
2.  Press grout diagonally into joints holding float at a 45-
degree angle. Make sure that joints are completely filled. 
3.  Remove all excess grout off vinyl tile by holding float at a 
90 degree angle and drawing diagonally across tile. 
4.  For best results, wait 10 minutes before beginning clean up 
to allow the grout joint some time to firm up so it is not 
pulled out of the joint during cleanup process. Do not wait 
longer than 40 minutes. 
5.  To clean, first soak sponge in cool clean water. Wring out 
most excess water, then pat the surface of the tile with the 
damp sponge to loosen the film. Next, rinse the sponge in 
water a second time and wring out excess water 
completely. 
6.  Use the damp sponge in a light, circular motion to smooth 
joints and clean film from the tile. Avoid using excessive 
amounts of water on the grout joints. 
7.  Turn sponge over to a clean side and draw diagonally 
across tiles to remove any remaining film. 
8.  For optimal results, follow these final clean-up steps: 
moisten a towel with clean water, wring out excess, and 
then drag damp towel across surface diagonally. This will 
pick up remaining film. 
©2015 H.B. Fuller Construction Products Inc. 
Form # TSSMPP R1014-16 
1105 South Frontenac Street 
Aurora, IL 60504-6451 U.S.A. 
tecskillset.com 
TEC and Skill Set are trademarks of 
H.B. Fuller Construction Products Inc. 
9.  If a light haze remains after cleaning, do not attempt to 
remove it with the sponge. Instead, leave the haze on the 
surface and remove the next day with a damp sponge. 
Haze will easily come off most tile surfaces. 
10.  There is no need to seal TEC® Skill Set™ Ready to Use 
Grout. 
Note: If excess water is used in the sponge during clean up, minor cracks or 
pinholes can develop. If the grout is over-worked, it may appear to shrink 
down into joint. Should any of these things occur, simply apply a second coat 
to the affected areas. You must allow your initial application to cure for 24 
hours prior to your second application. 
Instruction for Use over Premixed and Cement-Based Grout 
To install, existing premixed or cementitious grout must be clean, 
sealer free, and 1/8” lower than tile surface. If not: remove existing 
grout with a grout saw to at least 1/8” below the surface of tile. Make 
sure the joint is free of all dust and debris, then apply grout per 
instructions above. 
Set-up Time 
Light foot traffic after 24 hours. Allow 7 days to achieve final cure 
which includes hardness and stain resistance. ALLOW 7 DAYS 
BEFORE EXPOSURE TO WATER. 
Clean Up 
Clean tools and hands with warm soapy water while grout is still wet.  
Maintenance 
For routine cleaning of your grout, use a Neutral pH cleaner. Follow 
manufacturer instructions for dilution. 
Do not use acids, bleaches or vinegar for cleaning. Alkaline-based 
cleaners can be used for periodic heavy duty cleaning. Follow 
manufacturer instructions for dilution. 
6. WARRANTY 
For details about our limited warranties, see your sales associate or 
tecskillset.com. 
7. TECHNICAL SERVICES 
Technical Assistance 
Information is available by calling the Technical Service Helpline. 
Toll Free: 800-832-9023 
Fax: 630-952-1235 
Technical and Safety Literature 
To acquire technical and safety literature, please visit our website at 