Installation Instructions
Product Data
1. PRODUCT NAME
TEC
®
 Indoor/Outdoor Carpet Adhesive 
(975)
2. MANUFACTURER
H.B. Fuller Construction Products Inc. 
1105 South Frontenac Street 
Aurora, IL 60504-6451 U.S.A. 
800.552.6225 Office 
800.952.2368 Fax 
tecspecialty.com
3. DESCRIPTION
TEC
®
 Indoor/Outdoor Carpet Adhesive is specifically designed for the installation 
of most outdoor carpets and is water resistant when cured.
Key Features and Benefits
• Outdoor residential and commercial use
• Bonds to pressure-treated lumber
• Water resistant when dry
• Contributes to LEED
®
 project points
• Zero VOC
Packaging
1 quart plastic pails (.946 L)  Product #7047485117
1 gallon plastic pails (3.79 L)  Product #7047485017
3.5 gallon plastic pails (13.24 L)  Product #7047481217
Coverage
Coverage will vary with the absorption of substrate and trowel size. Figures below 
are presented only as guidelines.
Flooring Type
Recommended  
Trowel Size
Approximate Coverage in sq. ft. (m
2
)
Quart Gallon 3.5 Gallon
Rough-textured 
carpet backings
1
⁄
8
" x 
1
⁄
8
" x 
1
⁄
8
"
(3 x 3 x 3 mm)
V-notch trowel
20-27.5
(1.9-2.6)
80-110
(7.4-10.2)
280-385
(26.0-35.8)
Marine or light 
textured backings
3
⁄
32
" x 
3
⁄
32
" x 
3
⁄
32
"
(2.4 x 2.4 x 2.4 mm)
V-notch trowel
22.5-30
(2.1-2.8)
90-120
(8.4-11.1)
315-420
(29.3-39.0)
Suitable Substrates
When properly prepared, suitable substrates include:
• Exterior grade plywood
• Marine grade plywood 
• Association-grade plywood (interior only)
• Pressure-treated lumber
• Concrete (fully cured, free from hydrostatic pressure and moisture vapor 
emissions)
• Cement-based patches and leveling compounds (interior only unless approved 
for exterior use)
Approved Flooring
• Carpet and artificial grass, both indoors and outdoors, with backings such as 
rubber-backed, ActionBac
®
* and non-backed. 
*ActionBac
®
 is a registered trademark of Propex Inc.
Storage
Freeze/thaw stable to 10°F. Avoid prolonged or repeated freeze thaw cycles. If 
frozen, slowly bring to room temperature and stir before using.
Shelf Life
Maximum of 1 year from date of manufacture in unopened container.
Limitations
• NOT FOR USE OVER PRESSURE TREATED PLYWOOD. 
• Do not use over lauan, water sealed, painted, stained, or varnished surfaces. 
• Do not use with PVC or vinyl backed carpet. 
• Protect from freezing. 
• Protect from physical damage. 
• Accepts light traffic in 12 hours and full traffic in 24 hours; full cure takes  
48 hours. 
• The finished installation must be protected from moisture and/or freezing for a 
minimum of 24 hours. 
• Do not install in temperatures below 50°F.  
• Do not reuse container. Dispose of container and adhesive residue in 
accordance with federal, state and local waste disposal regulations. 
• DO NOT flush adhesive down drains. 
• Do not use over metal.
Cautions
Read complete cautionary information printed on product container prior to use. 
For medical emergency information, call 1-888-853-1758.
This Product Data Sheet has been prepared in good faith on the basis of information  
available at the time of publication. It is intended to provide users with information 
about and guidelines for the proper use and application of the covered TEC
®
 brand 
product(s) under normal environmental and working conditions. Because each 
project is different, H.B. Fuller Construction Products Inc. cannot be responsible 
for the consequences of variations in such conditions, or for unforeseen conditions.
4. TECHNICAL DATA
Physical Properties
TEC
®
 Indoor/Outdoor Carpet Adhesive (975)
Description
Physical State Medium paste
Color Tan
Odor Nil
Open Time 20-30 minutes
VOC/Liter of Material 0 g/L (calculated)
5. INSTALLATION INSTRUCTIONS
Substrate Preparation
For use over concrete above, on or below grade, exterior or marine grade 
plywood. Not recommended over painted, stained and/or water-sealed plywood. 
Sweep floor and remove loose dust and debris immediately prior to installation. 
Make sure floor is free from grease, oil, paint and any other contaminants that 
will interfere with the bond of the adhesives. Fill all cracks and depressions 
with a suitable exterior-grade floor-patching compound. Condition adhesive and 
materials to 65ºF and 35-65% relative humidity, 48 hours prior to and after 
installation. 
All concrete substrates must be tested for moisture and pH prior to flooring 
installation. The industry standard methods for testing moisture are ASTM 
F2170 (RH) or ASTM F1869 (Calcium Chloride-MVER). Consult floor covering 
manufacturer for acceptable RH or MVER. Test for pH in accordance with ASTM 
F710. pH range of 7-9 is required. Moisture vapor emissions not to exceed 3 
lbs./1000 ft
2
/24 hours.
Application
Apply adhesive evenly to the substrate using the appropriate trowel as shown 
in the Coverage section. Avoid applying adhesive in direct sunlight, high 
temperatures or excessive wind. Apply only as much adhesive as can be 
covered in 20 minutes. Lay the flooring into the adhesive within 20 minutes 
after troweling. Lift a corner of material periodically to see that the adhesive 
Indoor/Outdoor Carpet Adhesive