How to Guide

Ready to Use Grout
Physical Properties
TEC® Skill Set™ Ready to Use Grout
Description
Physical State
Paste
Color
Available in 8 standard colors
Initial Cure [at 72º (22ºC)]
24 hours
Final Cure
7 days
VOC/Liter of Material
28 grams less water and
exempt compounds
Foot Traffic Rating (ASTM C627)
Residential
Storage
Store in a cool, dry location.
Do not store open containers.
Freeze/thaw stable
Shelf Life
Maximum of 18 months from
date of manufacture in
properly stored, unopened
package.
5. Installation Instructions
Surface Preparation
Area must be clean, dry, free of dirt and dust. Grout joint should be
free of sealers.
Application
1. Grout no more than 10 sq. ft. at a time.
2. Press grout diagonally into joints holding float at a 45-
degree angle. Make sure that joints are completely filled.
3. Remove all excess grout off vinyl tile by holding float at a
90 degree angle and drawing diagonally across tile.
4. For best results, wait 10 minutes before beginning clean up
to allow the grout joint some time to firm up so it is not
pulled out of the joint during cleanup process. Do not wait
longer than 40 minutes.
5. To clean, first soak sponge in cool clean water. Wring out
most excess water, then pat the surface of the tile with the
damp sponge to loosen the film. Next, rinse the sponge in
water a second time and wring out excess water
completely.
6. Use the damp sponge in a light, circular motion to smooth
joints and clean film from the tile. Avoid using excessive
amounts of water on the grout joints.
7. Turn sponge over to a clean side and draw diagonally
across tiles to remove any remaining film.
8. For optimal results, follow these final clean-up steps:
moisten a towel with clean water, wring out excess, and
then drag damp towel across surface diagonally. This will
pick up remaining film.
©2015 H.B. Fuller Construction Products Inc.
Form # TSSMPP R1014-16
1105 South Frontenac Street
Aurora, IL 60504-6451 U.S.A.
tecskillset.com
TEC and Skill Set are trademarks of
H.B. Fuller Construction Products Inc.
9. If a light haze remains after cleaning, do not attempt to
remove it with the sponge. Instead, leave the haze on the
surface and remove the next day with a damp sponge.
Haze will easily come off most tile surfaces.
10. There is no need to seal TEC® Skill Set™ Ready to Use
Grout.
Note: If excess water is used in the sponge during clean up, minor cracks or
pinholes can develop. If the grout is over-worked, it may appear to shrink
down into joint. Should any of these things occur, simply apply a second coat
to the affected areas. You must allow your initial application to cure for 24
hours prior to your second application.
Instruction for Use over Premixed and Cement-Based Grout
To install, existing premixed or cementitious grout must be clean,
sealer free, and 1/8” lower than tile surface. If not: remove existing
grout with a grout saw to at least 1/8” below the surface of tile. Make
sure the joint is free of all dust and debris, then apply grout per
instructions above.
Set-up Time
Light foot traffic after 24 hours. Allow 7 days to achieve final cure
which includes hardness and stain resistance. ALLOW 7 DAYS
BEFORE EXPOSURE TO WATER.
Clean Up
Clean tools and hands with warm soapy water while grout is still wet.
Maintenance
For routine cleaning of your grout, use a Neutral pH cleaner. Follow
manufacturer instructions for dilution.
Do not use acids, bleaches or vinegar for cleaning. Alkaline-based
cleaners can be used for periodic heavy duty cleaning. Follow
manufacturer instructions for dilution.
6. WARRANTY
For details about our limited warranties, see your sales associate or
tecskillset.com.
7. TECHNICAL SERVICES
Technical Assistance
Information is available by calling the Technical Service Helpline.
Toll Free: 800-832-9023
Fax: 630-952-1235
Technical and Safety Literature
To acquire technical and safety literature, please visit our website at
tecskillset.com.