Installation Instructions

Product Data
Universal Pressure Sensitive Adhesive
1. PRODUCT NAME
TEC
®
Universal Pressure-Sensitive Flooring Adhesive
(747)
2. MANUFACTURER
H.B. Fuller Construction Products Inc.
1105 South Frontenac Street
Aurora, IL 60504-6451 U.S.A.
800.552.6225 Office
800.952.2368 Fax
tecspecialty.com
3. DESCRIPTION
Universal Pressure-Sensitive Flooring Adhesive is a high quality, high strength,
adhesive with excellent resistance to plasticizer migration. Can be used for
installation of carpet tile, fiberglass backed sheet vinyl and self stick vinyl tiles.
Key Features and Benefits
• Easy to apply with paint roller
• Provides quick tack development
For luxury vinyl tile, fiberglass-reinforced vinyl flooring, self stick vinyl tiles and
vinyl-backed carpet tile
Packaging
1 quart plastic pails (.946 L) Product #7130885117
1 gallon plastic pails (3.79 L) Product #7130885017
3.5 gallon plastic pails (13.24 L) Product #7130881217
Coverage
Coverage will vary with the absorption of substrate and trowel size. Figures below
are presented only as guidelines.
Flooring Type
Recommended
Trowel Size
Approximate Coverage in sq. ft. (m
2
)
Quart Gallon 3.5 Gallon
Resilient
sheetgoods;
resilient floor tile
1
16
" x
1
16
" x
1
16
"
(1.6 x 1.6 x 1.6 mm)
square-notch trowel
40.5-45
(3.8-4.2)
160-180
(14.9-16.7)
560-630
(52.0-58.5)
Resilient
sheetgoods
installed over
existing resilient
1
32
" x
1
32
" x
1
32
"
(0.8 x 0.8 x 0.8 mm)
square-notch trowel
75-87.5
(7.0-8.1)
300-350
(27.9-32.5)
1050-1225
(97.5-113.8)
Brush or rolled
56.2-65
(5.2-6.0)
225-260
(20.9-24.2)
787.5-910
(73.-84.5)
Suitable Substrates
When properly prepared, suitable substrates include:
Concrete Marble
Terrazzo Metal
Plywood - APA standard underlayment grade or better
Multiply underlayment
Fiber-cement underlayment
Latex portland cement based underlayment
Well bonded, smooth, wax-free, existing single layer non-cushioned resilient
flooring
Properly installed radiant heated subfloors where the surface temperature does
not exceed 85°F.
Approved Flooring
Self stick vinyl tiles
Fiberglass backed sheet vinyl
Modular carpet tiles (including enhancer, recycled, vinyl and fiberglass backed)
Cushions include but are not limited to: All approved double-bond cushions
Storage
Store inside at temperatures of 60°F to 100°F. Best to keep from freezing. If
frozen, allow to thaw before use. Keep container tightly closed when not in use.
Always store in an upright position.
Shelf Life
Maximum of 18 months from date of manufacture in unopened container.
Limitations
Do not use where hydrostatic pressure, excessive moisture vapor emissions, or
alkali is present.
New concrete should be allowed to cure a minimum of 60-90 days prior to
installation.
Do not use when temperature is below 60°F.
Not recommended for installation over cushion-backed or unprepared
embossed sheetgoods, lauan or unprimed gypsum.
Restrict heavy foot traffic or rolling loads for at least 24 hours.
Do not expose to water from cleaning or other sources for a minimum of 30 days.
Not for exterior or marine applications.
Cautions
Read complete cautionary information printed on product container prior to use.
For medical emergency information, call 1-888-853-1758.
This Product Data Sheet has been prepared in good faith on the basis of information
available at the time of publication. It is intended to provide users with information
about and guidelines for the proper use and application of the covered TEC
®
brand
product(s) under normal environmental and working conditions. Because each
project is different, H.B. Fuller Construction Products Inc. cannot be responsible
for the consequences of variations in such conditions, or for unforeseen conditions.
4. TECHNICAL DATA
Physical Properties
TEC
®
Universal Pressure-Sensitive Flooring Adhesive (747)
Description
Physical State Paste
Color Off-white
Odor Nil
Open Time 1-24 hours at 75°F/50% RH
Final Cure 24-48 hours
VOC/Liter of Material 0 g/L (calculated)
5. INSTALLATION INSTRUCTIONS
Substrate Preparation
For best results, flooring material, room and adhesive should be kept at a
minimum of 70°F for 48 hours before and 24 hours after installation. Remove
all wax, grease, oil, paint, dust, curing compounds, adhesive residue and other
surface contaminants. Plywood should be installed according to American
Plywood Association guidelines. Plywood subfloor surfaces should be well
nailed at all edges and through center. Raised edges should be sanded smooth.
Fill cracks and depressions in floor with a surface preparation product. Sand
smooth and vacuum to remove dust. On hardwood and wood parquet floors, the
installation of plywood or fiber-cement underlayment is required.
All concrete substrates must be tested for moisture and pH prior to flooring
installation. The industry standard methods for testing moisture are ASTM
F2170 (RH) or ASTM F1869 (Calcium Chloride-MVER). Consult floor covering
manufacturer for acceptable RH or MVER. Test for pH in accordance with ASTM
F710. Range of 7-9 is required.
VOC 0 g/L