Installation Sheet
2
COM X1 X2 X3 X4
Install the Remote Transformer
NOTE: In order to use small gage wires from the
transformer to the electrical box, it is recommended to
install the remote transformer near (if possible) the
electrical box. See "Low Voltage Wire Size Table"
below.
Mount the transformer to a solid surface using the
keyhole slot on the mounting bracket (hardware not
included).
Remove the transformer cover by loosening the two
Phillips screws on the side of the transformer.
TRANSFORMER
BRACKET
TRANSFORMER
BRACKET
PHILLIPS
SCREW
COM X1 X2 X3 X4
Install a conduit and power line wires from the panel to
remote transformer.
Do not connect the power line wires to the panel at this
time.
Connect the 120V black transformer wire to the hot
power line wire with a wire nut.
Connect the 120V white transformer wire to the neutral
power line wire with a wire nut.
Connect the ground wire to the green wire or stud
labeled “ground” in the console.
HOT POWER
LINE WIRE
NEUTRAL
POWER
LINE WIRE
CONDUIT
TRANSFORMER
WATTAGE
WIRE SIZE
FOR 5 FT
WIRE SIZE
FOR 6-15 FT
WIRE SIZE
FOR 16-20 FT
WIRE SIZE
FOR 21-40 FT
WIRE SIZE
FOR 40-60 FT
WIRE SIZE
FOR 61-90 FT
LOW VOLTAGE WIRE SIZE TABLE
150 WATT #8 GA #6 GA #4 GA #2 GA #1 GA#12 GA
TRANSFORMER COVER
1A1A
1A
1B
1
2
3
4
5
6
7
1
2
2
3
4
5
6
7
1