Installation Sheet





2
1
4
5
N
L
2
3


















































































































DRIVER
L
N
3A
Connect the fixture ground wire to a suitable ground in
accordance with local electrical codes.
Connect the red driver wire labeled “L to the fixture
coaxial cable labeled “L with a wire nut.
Connect the black driver wire labeled “N” to the fixture
coaxial cable labeled “N” with a wire nut.
Connect the black 120V input to the hot power line wire
with a wire nut.
Connect the white 120V input to the neutral power line
wire with a wire nut.
Skip to section 6.
2
3
4
5
Wire the Fixture (for 30”)
2A
1
2
3
Shorten the Cords for 24” (Optional)
NOTE: If shortening is necessary, ensure that the
cable identifiers are not removed during installation.
If no shortening is necessary, skip to section 3A.
N
Leave 6" behind for wire connections, cut off the excess
cord. NOTE: This fixture contains one dummy coaxial
cable.
From the end of the cord, strip the insulation and
braided conductor 4" using a sharp knife. Make sure
not to nick the center conductor wire.
Strip the end of the center conductor wire.








DUMMY COAXIAL CORD
CENTER
CONDUCTOR WIRE






















4A
1
2
3
Leave 6" behind for wire connections, cut off the excess
cord. NOTE: This fixture contains one dummy coaxial
cable.
From the end of the cord, strip the insulation and
braided conductor 4" using a sharp knife. Make sure
not to nick the braided conductor and center
conductor wire.
Without nicking the center wire conductor, make a
1/4” cut at the base of the exposed braided conductor
and pull the center conductor wire out. Make sure not
to further damage the braided conductor while
doing so.
Strip the end of the center conductor wire.




































DUMMY COAXIAL CORD
BRAIDED
CONDUCTOR
CENTER
CONDUCTOR WIRE
COAXIAL CORD
COAXIAL CORD
L
1
6
4
1
DRIVER DRIVER
















































































































4
4
3
2
L
N
N
L
5A
Connect the fixture ground wire to a suitable ground in
accordance with local electrical codes.
Connect the braided conductor wire from one of the
fixture cords to a black driver wire labeled “N” with a
wire nut.
Connect the center conductor wire from one of the
fixture cords to a red driver wire labeled “L with a wire
nut.
Repeat step 1-3 for the other fixture cord.
1
2
3
Wire the Fixture (for 24”)
Shorten the Cords for 30” (Optional)
NOTE: If no shortening is necessary, skip to section 5A.
4