Installation Sheet
Ground the canopy in accordance with local electrical
code.
Connect the white transformer wire to the neutral
power line wire with a wire nut.
Connect the black transformer wire to the hot power
line wire with a wire nut.
Place the transformer and all the wires inside the
electrical box. Use the adhesive pad to secure the
transformer in the electrical box.
Mount the canopy crossbar to the electrical box with
the two long #8-32 screws.
POWER LINE WIRES
TRANSFORMER
WIRES
#8-32 SCREW
CANOPY
CROSSBAR
CEILING
ELECTRICAL BOX
1
2
3
4
5
1
2
3
5 5
1
FREEJACK
GP I :ENERAL RODUCT NFORMATION
This product is suitable for indoor dry locations only.
This fixture is intended to be used utilizing NEC
compliant junction boxes with enough room to house the
transformer.
LED Driver Dimensions: 2-3/4" X 1-5/8" X 7/8
This product can be dimmed with a low-voltage
electronic dimmer and has a rated maximum output of
60 watts.
For Wood Canopies: Do not install any head or pendant
closer than 12 inches to this canopy. Heat from the lamp
may damage the wood finish.
SAVE THESE INSTRUCTIONS!
CAUTION RISK OF FIRE-
This product must be installed in accordance with the
applicable installation code by a person familiar with
the construction and operation of the product and the
hazards involved.
Use minimum 90°C supply conductors.
Installation Instructions for
920 4FJ RCN
4” Freejack Canopy
1.0
2.9
700 4 _, 700 4 _FJ SQ FJ RF
1
1A