Installation Sheet
3
Loosen (do not remove) the set screws on the canopy
strain relief on the side which needs adjusting.
Evenly and gently pull out the coaxial cable, in very small
increments, through the strain relief to adjust whichever
side to level the fixture.
Ensure that the fixture is level and re-tighten the set
screw on the strain relief.
STRAIN RELIEF
1
7A
2
2
Additional Leveling (optional)
NOTE: If necessary, minor leveling adjustments to
the fixture may be needed. It is recommended that
one person hold the fixture straight with the use of
a level while the other adjusts the coaxial cable.
CAUTION: Only pull out extra cable for leveling if
enough cord was left behind the canopy. Minimal
amounts of cord should be pulled out for fine
leveling.
3
1
CAUTION: Make sure to support the fixture if fine
leveling is necessary.
N
5
6
DRIVER DRIVER
-
+
+
5B
Connect the black 120V input wires from each driver to
the hot power line wire with a wire nut.
Connect the white 120V input wires from each driver to
the neutral power line wire with a wire nut.
For 277V Only: If using 0-10V dimming, connect the
purple and gray wires to a compatible dimmer. If not
using 0-10V dimming, cap off the purple and gray wires.
Neatly place all cables, wires, and wire nut connections
inside the canopy, align the canopy holes with the
mounting plate holes, and secure the canopy in place by
tightening the canopy screws using the provided Allen
wrench (reversal of section 1A).
5
6
7
8