Installation Sheet

2
Connecting the MonoRail to the
Power Feed Canopy
Unscrew the housing nipple from the housing.
Loosen the #6-32 set screw on the housing nipple with
1/16 Allen wrench.
Place the MonoRail into the housing. Screw the housing
nipple to the housing tight by twisting the housing
nipple clockwise.
Tighten the #6-32 set screw with the 1/16 Allen wrench.
1/16 ALLEN
WRENCH
#6-32 SET SCREW
MONORAIL
HOUSING NIPPLE
HOUSING
2A
1
2
3
4
3
2
4
Tighten the 3/8-24 set screw on the bottom of the
housing with the 3/16 Allen wrench.
3/8-24 SET SCREW
3/16 ALLEN
WRENCH
SAVE THESE INSTRUCTIONS!
2B
5
5
7400 Linder Ave, Skokie, IL 60077
847.410.4400
www.techlighting.com
© 2016 Tech Lighting, L.L.C. All rights reserved. The "Tech Lighting" graphic is
a registered trademark of Tech Lighting, L.L.C. Tech Lighting reserves the right
to change specifications for product improvements without notification.
A Generation Brands Company
Important Safety Information
To reduce the risk of fire and burns, do not install this
lighting system where the uninsulated open bus bar
conductors can be shorted or contact any conductive
materials.
To reduce the risk of the system overheating and possibly
causing a fire, make sure all the connections are tight.
Do not install fixture assemblies closer than 6 inches to
curtains or similarly combustible materials.
Turn the electrical power off before modifying the lighting
system in any way.
The fixtures used with the system must be identified to be
used with the corresponding system.
Minimum volume of the electrical box must be 6 cubic
inches (98 cubic centimeter).
Load the circuit of the remote transformers to no more than
the maximum rated capacity as specified.
To reset the electronic surface transformer, turn the power
off then on (main power, breaker panel, or wall switch).