Installation Sheet

1.9
Installation Instructions for
Single Power Feed Canopies
700MOP_C0_
1
920MOPC1C
GP I :ENERAL RODUCT NFORMATION
This fixture is intended to be installed utilizing
NEC compliant junction boxes with a minimum
depth of 2”.
Minimum volume of the junction box must be 6 cubic inches
(98 cubic centimeter).
This product is suitable for indoor dry locations only.
PFCOWER EED ANOPIES
NOTE: The remote transformer should be installed
prior to these steps. Refer to the instructions
provided with the remote transformer.
Install the 2" Square Power Feed
Canopy
Connect the power feed canopy wires to the low
voltage wires coming from the remote transformer in
the 2" electrical box with wire nuts.
Mount the 2" square canopy to the 2" electrical box with
the two #4-40 screws.
2" ELECTRICAL BOX
CEILING
WIRE NUT
#4-40
SCREWS
DRESSING
PLATE
LOW VOLTAGE
TRANSFORMER WIRES
NOTE: The 2" Electrical box should be installed prior
to these steps. Refer to the instructions provided
with the 2" electrical box.
Install the 4" Round Standard and
Low Profile Power Feed Canopy
Connect the power feed canopy wires to the low
voltage wires coming from the remote transformer in
the electrical box with wire nuts.
Mount the 4" round power feed canopy to the electrical
box with the two #8-32 screws.
LOW VOLTAGE
TRANSFORMER WIRES
#8-32 ROUND
HEAD SCREW
4" ROUND
CANOPY
CEILING
ELECTRICAL BOX
NOTE: Use the provided universal round crossbar
when the canopy holes do not line up with the
electrical box holes.
NOTE: When extending the MonoRail power feed
canopy, refer to the instructions provided with the
power feed extenders before following the steps
below.
1A
2A
1
2
2
1
2
1
2
1
1