Installation Sheet
3
Important Safety Information
Do not conceal or extend bus bar conductors through a
building wall.
To reduce the risk of fire and burns, do not install this
lighting system where the uninsulated open bus bar
conductors can be shorted or contact any conductive
materials.
To reduce the risk of the system overheating and possibly
causing a fire, make sure all the connections are tight.
Do not install fixture assemblies closer than six inches to
curtains or similarly combustible materials.
Turn the electrical power off before modifying the lighting
system in any way.
The fixtures used with the system must be identified to be
used with the corresponding system.
Minimum volume of the electrical box must be 6 cubic
inches (98 cubic centimeter).
Load the circuit of the remote transformers to no more than
the maximum rated capacity as specified.
To reset the electronic surface transformer, turn the power
off then on (main power, breaker panel, or wall switch).
Connect the Transformer to the
MonoRail
Unscrew the housing from the housing nipple.
Loosen the #6-32 set screw on the housing nipple with
the 1/16 Allen wrench.
Place the MonoRail into the housing. Screw the housing
nipple to the housing tight by twisting the housing
nipple clockwise.
Tighten the #6-32 set screw on the housing nipple with
the 1/16 Allen wrench.
Tighten the 3/8-24 set screw on the bottom of the
housing with the 3/16 Allen wrench.