Specification Sheet
Table Of Contents
SPECIFICATIONS
HA R DWA RE M ATERIA LHA R DWA RE M ATERIA L Metal
SHA DE M ATERIALSHA DE M ATERIAL Glass
NET WEIGHTNET WEIGHT 3.5 lbs
HEIG HTHEIG HT 13.3in
WIDTHWIDTH 3.5in
LENG THLENG TH 3.5in
UP LIG H T / DOW N LIG H T / BOTH ?UP LIG H T / DOW N LIG H T / BOTH ?
WET LISTEDWET LISTED
DA M P LISTEDDA M P LISTED Yes
DRY LIS TEDDRY LIS TED
M IN. HA NG IN G HEIG HTM IN. HA NG IN G HEIG HT 19.8in
M A X H A NG ING HEIGHTM A X HANG ING HEIG HT 157.8in
TOTA L CORD LENG THTOTA L CORD LENG TH 144in
TOTA L STEM LENG THTOTA L STEM LENG TH
STEM QTYSTEM QTY
SLOPED C EILING A DAPTABLE?SLOPED C EILING A DAPTABLE? Yes 45° Max
G ENERA L LISTINGG ENERAL LISTING ETL Listed
INC LUDESINC LUDES
MANETTE MEDIUM PENDANT
LAMPING SPECIFICATIONS
LED LA M PLED LA M P INTEG RA TED LEDINTEG RA TED LED NON LEDNON LED NO LAM PNO LA M P
DELIV ERED LUM ENSDELIV ERED LUM ENS 700
WA TTSWA TTS 15
M A X WATTA G E PER BU LBM A X WATTA G E PER BU LB 15W
INP U T V OLTAG EINP U T V OLTAG E
120VV
277VV
DIM M ING TYPE*DIM M ING TYPE*
Clear Glass, Transparent Smoke Glass : ELV,
TRIAC
Clear Glass, Transparent Smoke Glass : 0-10V
CC TCC T 3000K
CR ICR I 90 CRI
LED LIFETIM ELED LIFETIM E
L70L70 >50000
AV ERAG E BULB HOU RSAV ERAG E BULB HOU RS
FIELD S ERV ICEABLE LEDFIELD S ERV ICEABLE LED
LAM P BA S ELAM P BA S E Integrated LED
LAM P S H A P ELAM P S H A P E Integrated LED
LAM P IN CLUDED?LAM P IN CLUDED? True
WA R RANTY **WA R RANTY ** 5 Years
* Dimming information available at www.techlighting.com/Downloads#dimming
** Visit techlighting.com for specific warranty limitations and details.
T20 / T24 / JA8 INFORMATION
Integ ratedInteg rated
LEDLED
Re place m entRe placem e nt
LED Lam pLED Lam p
NoNo
Lamp *Lam p *
This product can be used to comply with
California Building Energy Efficiency
Standards 2016 Title 24Title 24 Part 6 / JA8.
Yes
This product can be used to comply with
California Appliance Efficiency Standards
2016 Title 20Title 20 and may be shipped to and
sold in California.
N/A
* If a light fixture or component does not include a lamp or light source, it is the responsibility of the
customer to select a lamp that meets the T24 and T20 requirements.
© 2019 Tech Lighting, L.L.C. All rights reserved. The “Tech Lighting” graphic is a registered trademark of Tech Lighting, L.L.C. Tech
Lighting reserves the right to change specifications for product improvements without notification.
7400 Linder Avenue, Skokie, IL 60077
T 847.410.4400 | F 847.410.4500 | techlighting.com