Installation Instructions
1
Installation Instructions for
GP I :ENERAL RODUCT NFORMATION
These fixtures are intended to be installed utilizing
NEC compliant junction boxes.
This product is suitable for damp locations.
Incandescent lamps may be dimmed with a standard incandescent
dimmer. LED lamps may be dimmed with a LED dimmer. Consult
lamp manufacturer for additional information.
1.0
CAUTION RISK OF FIRE-
This product must be installed in accordance with
the applicable installation code by a person familiar
with the construction and operation of the product
and the hazards involved.
Use minimum 90°c supply conductors.
Wall
Remove the fixture screws located on the top and bottom of the fixture base using a screw driver, then remove the mounting plate from
the fixture base.
Install the mounting plate onto the electrical box with the two #8-32 screws provided.
Connect the fixture to suitable ground in accordance with local electrical codes.
Connect the white fixture wire to the neutral power line wire with a wire nut.
Connect the black fixture wire to the hot power line wire with a wire nut.
Properly place all wires and wire nut connections into the electrical box, mount the fixture back onto the mounting plate, and reinstall
fixture screws (reversal of step 1).
1
2
1A
Install the Fixture
3
4
5
6
SAVETHESE INSTRUCTIONS!
5
4
1
1
2
MOUNTING PLATE
FIXTURE
FIXTURE SCREW
Wall