Installation Manual
248 Configuring Intelligent Platform Management Interface
Configuring IPMI Using the RACADM CLI
1
Login to the remote system using any of the RACADM interfaces. 
See "Using RACADM Remotely" on page 110.
2
Configure IPMI over LAN.
Open a command prompt, type the following command, and press 
<Enter>:
racadm config -g cfgIpmiLan -o cfgIpmiLanEnable 1
  NOTE: This setting determines the IPMI commands that can be executed 
from the IPMI over LAN interface. For more information, see the IPMI 2.0 
specifications.
a
Update the IPMI channel privileges.
At the command prompt, type the following command and press 
<Enter>:
racadm config -g cfgIpmiLan -o 
cfgIpmiLanPrivilegeLimit 
<level>
where 
<level>
 is one of the following:
•
2
 (User)
•
3
 (Operator)
•
4
 (Administrator)
For example, to set the IPMI LAN channel privilege to 2 (User), type 
the following command:
racadm config -g cfgIpmiLan -o 
cfgIpmiLanPrivilegeLimit 2
b
Set the IPMI LAN channel encryption key, if required.
  NOTE: The iDRAC6 IPMI supports the RMCP+ protocol. See the IPMI 2.0 
specifications for more information.
At the command prompt, type the following command and press 
<Enter>:
racadm config -g cfgIpmiLan -o 
cfgIpmiEncryptionKey 
<key>










