Installation Manual
Configuring Intelligent Platform Management Interface 249
where 
<key>
 is a 20-character encryption key in a valid 
hexadecimal format.
3
Configure IPMI Serial over LAN (SOL).
At the command prompt, type the following command and press 
<Enter>:
racadm config -g cfgIpmiSol -o cfgIpmiSolEnable 1
a
Update the IPMI SOL minimum privilege level.
  NOTE: The IPMI SOL minimum privilege level determines the minimum 
privilege required to activate IPMI SOL. For more information, see the IPMI 2.0 
specification.
At the command prompt, type the following command and press 
<Enter>:
racadm config -g cfgIpmiSol -o 
cfgIpmiSolMinPrivilege 
<level>
where 
<level>
 is one of the following:
•
2
 (User)
•
3
 (Operator)
•
4
 (Administrator)
For example, to configure the IPMI privileges to 2 (User), type the 
following command:
racadm config -g cfgIpmiSol -o 
cfgIpmiSolMinPrivilege 2
b
Update the IPMI SOL baud rate.
  NOTE: To redirect the serial console over LAN, ensure that the SOL baud rate 
is identical to your managed system’s baud rate. 
At the command prompt, type the following command and press 
<Enter>:
racadm config -g cfgIpmiSol -o 
cfgIpmiSolBaudRate 
<baud_rate>
where 
<baud_rate>
 is 9600, 19200, 57600, or 115200 bps.