Installation Manual
Configuring Intelligent Platform Management Interface 251
d
Set the IPMI serial channel minimum privilege level. 
At the command prompt, type the following command and press 
<Enter>:
racadm config -g cfgIpmiSerial -o 
cfgIpmiSerialChanPrivLimit 
<level>
where 
<level>
 is one of the following:
•
2
 (User)
•
3
 (Operator)
•
4
 (Administrator)
For example, to set the IPMI serial channel privileges to 2 (User), 
type the following command:
racadm config -g cfgIpmiSerial -o 
cfgIpmiSerialChanPrivLimit 2
e
Ensure that the serial MUX is set correctly in the BIOS Setup program.
• Restart your system.
• During POST, press <F2> to enter the BIOS Setup program.
•Click 
Serial Communication
.
•In the 
Serial Connection
 menu, ensure that 
External Serial 
Connector
 is set to 
Remote Access Device
.
• Save and exit the BIOS Setup program.
• Restart your system.
The IPMI configuration is complete.
If IPMI serial is in terminal mode, you can configure the following 
additional settings using 
racadm config cfgIpmiSerial
 commands:
• Delete control
•Echo control
• Line edit
• New line sequences
• Input new line sequences
For more information about these properties, see the IPMI 2.0 
specification.