Installation Manual
Power Monitoring and Management 289
Viewing the Health Status of the Power 
Supply Units 
The Power Supplies page displays the status and rating of the power supply 
units installed in the server.
Using the Web-Based Interface 
To view the health status of the power supply units: 
1
Log in to the iDRAC6 Web-based interface.
2
Select 
Power Supplies
 in the system tree. The 
Power Supplies
 page 
displays and provides the following information:
•
Power Supplies Redundancy Status
: The possible values are:
–
Full
: The power supplies installed in the system are of the same type 
and they are functioning properly. 
–
Lost
: In systems with two power supply units, the power supplies 
installed in the system are of different types or one of them is 
malfunctioning or removed. In systems with four power supply units, 
the power supplies installed in the system are of different types, or two 
or three units are malfunctioning or removed.
–
Disabled
: Only one of the power supplies is available. No redundancy 
exists.
–
Degraded
 (only in systems with four power supply units): Four power 
supply units are installed in the system but one of them is 
malfunctioning or removed.
•
Individual Power Supply Elements
: The possible values are:
–
Status
 displays the following:
•
OK 
indicates that the power supply unit is present and 
communicating with the server. 
•
Warning
 indicates that only warning alerts have been issued 
and corrective action must be taken by the administrator. If 
corrective actions are not taken, it could lead to critical or severe 
power failures that can affect the integrity of the server. 