Installation Manual
290 Power Monitoring and Management
•
Severe
 indicates at least one failure alert has been issued. Failure 
status indicates a power failure on the server, and corrective action 
must be taken immediately. 
–
Location 
displays the name of the power supply unit: PS-n, where n is 
the power supply number. 
–
Ty p e
 displays the type of power supply, such as AC or DC (AC-to-DC 
or DC-to-DC voltage conversion).
–
Input Wattage
 displays the input wattage of the power supply, which 
is the maximum AC power load that the system could place on the 
datacenter.
–
Max Wattage
 displays the maximum wattage of the power supply, 
which is the DC power available to the system. This value is used to 
confirm that sufficient power supply capacity is available for the 
system configuration.
–
Online Status
 indicates the power state of the power supplies: present 
and OK, input lost, absent, or predictive failure. 
–
FW Version 
displays the firmware version of the power supply.
 NOTE: The Max Wattage is different than Input Wattage because of the 
power supply efficiency. For example, if the efficiency of the power supply is 
89% and Max Wattage is 717W, the Input Wattage is estimated at 797W.
Using RACADM 
Open a Telnet/SSH text console to the iDRAC, log in, and type: 
racadm getconfig -g cfgServerPower