Installation Manual
58 Configuring the iDRAC6 Using the Web Interface
4
In the 
Platform Event Filters List 
table, do the following for the filter(s) 
that you want to configure:
• Select one of the following actions: 
• Reboot System
• Power Cycle System
• Power Off System
• No Action
•In the 
Generate Alert
 column, select the checkbox to enable alert 
generation or clear the checkbox to disable alert generation for the 
selected action.
  NOTE: Generate Alert must be enabled for an alert to be sent to any valid, 
configured destination (PET).
5
Click 
Apply
. The settings are saved.
Configuring Platform Event Traps (PET)
  NOTE: You must have Configure iDRAC permission to add or enable/disable an 
SNMP alert. The following options will not be available if you do not have 
Configure iDRAC permission.
1
Log in to the remote system using a supported Web browser.
2
Ensure that you have performed the procedures in "Configuring Platform 
Event Filters (PEF)" on page 57.
3
Click 
System
Alerts
Traps Settings
.
4
In the 
IPv4 Destination List 
or the 
IPv6 Destination List
, do the following 
for the 
Destination Number
 to configure the IPv4 or IPv6 SNMP alert 
destination:
a
Select or clear the 
State
 checkbox. A selected checkbox indicates that 
the IP address is enabled to receive the alerts. A clear checkbox 
indicates that the IP address is disabled for receiving alerts.
b
In 
Destination IPv4 Address 
or 
Destination IPv6 Address
, enter a 
valid platform event trap destination IP address.