Installation Manual
Configuring the iDRAC6 Using the Web Interface 75
Updating the iDRAC6 Firmware/System Services 
Recovery Image
  NOTE: If the iDRAC6 firmware becomes corrupted, as could occur if the iDRAC6 
firmware update progress is interrupted before it completes, you can recover the 
iDRAC6 using the iDRAC6 Web interface.
NOTE: The firmware update, by default, retains the current iDRAC6 settings. During 
the update process, you have the option to reset the iDRAC6 configuration to the 
factory defaults. If you set the configuration to the factory defaults, you must 
configure the network using the iDRAC6 Configuration Utility.
1
Open the iDRAC6 Web-based interface and log in to the remote system. 
2
Click 
iDRAC Settings
, and then click the 
Update
 tab.
3
In the 
Upload/Rollback (Step 1 of 3) 
page, click 
Browse 
to select the 
firmware image that you downloaded from 
support.dell.com
 or the System 
Services recovery image.
  NOTE: If you are running Firefox, the text cursor does not appear in the 
Firmware Image field.
For example:
C:\Updates\V1.0\<
image_name
>
. 
OR
\\192.168.1.10\Updates\V1.0\<image_name>
The default firmware image name is 
firmimg.d6
. 
Table 4-20. Automated System Recovery Agent Setting
Setting Description
Enabled Enables/disables the Automated System Recovery Agent. 
When checked, the Automated System Recovery Agent is 
enabled.










