Installation Manual
98 Advanced iDRAC6 Configuration
To configure iDRAC6 settings to enable serial connections using the iDRAC6 
Web interface, follow these steps:
1
Expand the 
System
 tree and click 
iDRAC Settings
.
2
Click the 
Network/Security
 tab and then click 
Serial
.
3
Select 
Enabled
 under the 
RAC Serial 
section.
4
Click 
Apply Changes
.
When you are connected serially with the previous settings, you should see a 
login prompt. Enter the iDRAC6 username and password (default values are 
root, calvin, respectively).
From this interface, you can execute such features as RACADM. For example, 
to print out the System Event Log, enter the following RACADM command:
racadm getsel
Configuring iDRAC for Direct Connect Basic Mode and Direct Connect 
Terminal Mode
Using RACADM, run the following command to disable the iDRAC6 
command line interface:
racadm config -g cfgSerial -o cfgSerialConsoleEnable 0
Then, run the following RACADM command to enable Direct Connect Basic:
racadm config -g cfgIpmiSerial -o 
cfgIpmiSerialConnectionMode 1
Or, run the following RACADM command to enable Direct Connect 
Terminal:
racadm config -g cfgIpmiSerial -o 
cfgIpmiSerialConnectionMode 0
You can perform the same actions using the iDRAC6 Web interface:
1
Expand the 
System
 tree and click 
iDRAC Settings
.
2
Click the 
Network/Security
 tab and then click 
Serial
.
3
Deselect 
Enabled
 under the 
RAC Serial
 section.
 For Direct Connect Basic:
Under the 
IPMI Serial
 section change the 
Connection Mode Settings
drop-down menu to 
Direct Connect Basic Mode
.