Figure 8.  Dell 2.5” Hard Drive Carrier 
12.2.2  Empty Drive Bays 
For the slots that are not occupied by drives, a carrier blank is provided to maintain proper cooling, 
maintain a uniform appearance to the unit, and provide EMI shielding.  
12.2.3  Diskless Configuration Support 
The system supports diskless configuration with no storage controller (SAS 6/iR, PERC 6i, PERC H200, 
or PERC H700) installed in the system. A 2.5” hard drive backplane is still installed in this 
configuration. 
12.2.4  Hard Drive LED Indicators 
Each disk drive carrier has two LED indicators visible from the front of the system. One is a green LED 
for disk activity and the other is a bicolor (green/amber) LED for status information. The activity LED 
is driven by the disk drive during normal operation. The bicolor LED is controlled by the storage 
enclosure processor (SEP) device on the backplane. Both LEDs are used to indicate certain conditions 
under direction of a storage controller.  
For more information, see the Hard-Drive Indicator Patterns section in the About Your System 
chapter in the Dell PowerEdge R610 Systems Hardware Owner’s Manual on Support.Dell.com
. 
12.3 RAID Configurations 
See Table 11 for information on factory RAID configurations. For information on additional 
configurations, visit Dell.com
. 
Table 11.  Factory RAID Configurations 
Non-Mixed Drives 
All SATA, all SAS, or 
all SSD  
All 2.5” Drives 
Config 
Type 
Configs   Description  Min HDD  Max HDD 
No HDD
0
NZC
No controller/No hard drive
0
0
SAS or 
SATA—No 
RAID
1  MSS 
Integrated SAS/SATA (SAS 6/iR, 
PERC H200), No RAID
1  6 