Non-Mixed Drives
All SATA, all SAS, or
all SSD
All 2.5 Drives
Config
Type
Configs Description Min HDD Max HDD
SAS or
SATA
RAID
2 MSSR0
Integrated SAS/SATA RAID 0
(SAS 6/iR, PERC 6/i, PERC H200,
PERC H700)
1 6
3 MSSR1
Integrated SAS/SATA RAID 1
(SAS 6/iR, PERC 6/i, PERC H200,
PERC H700)
2 2
4 MSSR5
Integrated SAS/SATA RAID 5
(PERC 6/i, PERC H700)
3 6
5 MSSR10
Integrated SAS/SATA RAID 10
(PERC 6/i, PERC H700)
4 6
6 MSSR0/R0
Integrated SAS/SATA RAID 0/RAID 0
(SAS 6/iR, PERC 6/i, PERC H200,
PERC H700)
1 + 1 6
7 MSSR1/R1
Integrated SAS/SATA RAID 1/RAID 1
(SAS 6/iR, PERC 6/i, PERC H200,
PERC H700)
2 + 2 2 + 2
8 MSSR1/R5
Integrated SAS/SATA RAID 1/RAID 5
(PERC 6/i, PERC H700)
2 + 3 2 + 4
9 MSSR1/R10
Integrated SAS/SATA RAID 1/RAID
10 (PERC 6/i, PERC H700)
2 + 4 2 + 4
10 MSSR6
Integrated SAS/SATA RAID 6
(PERC 6/i, H700)
4 6
SAS or
SATA
SSDs
RAID
16 MSSR1
Integrated SSD RAID 1
(PERC 6/i, PERC H200, H700)
(SAS SSD with PERC H200, PERC
H700 only)
2 2
17 MSSR5
Integrated SSD RAID 5
(PERC 6/i, PERC H700)
(SAS SSD with PERC H700 only)
3 6
18 MSSR10
Integrated SSD RAID 10
(PERC 6/i, PERC H200, PERC H700)
(SAS SSD with PERC H200, PERC
H700 only)
4 6
SATA
SSD—No
RAID
19 MSS
Integrated SATA SSD, No RAID
(PERC H200)
1 1