Installation Manual

196 Configuring iDRAC6 for Single Sign-On or Smart Card Login
Troubleshooting the Smart Card Logon in iDRAC6
Use the following tips to debug an inaccessible Smart Card:
ActiveX plug-in unable to detect the Smart Card reader
Ensure that the Smart Card is supported on the Microsoft Windows
operating system. Windows supports a limited number of Smart Card
cryptographic service providers (CSPs).
Tip: As a general check to see if the Smart Card CSPs are present on a
particular client, insert the Smart Card in the reader at the Windows logon
(Ctrl-Alt-Del) screen and check to see if Windows detects the Smart Card
and displays the PIN dialog-box.
Incorrect Smart Card PIN
Check to see if the Smart Card has been locked out due to too many attempts
with an incorrect PIN. In such cases, the issuer of the Smart Card in the
organization will be able to help you get a new Smart Card.
Unable to Log into Local iDRAC6
If a local iDRAC6 user cannot log in, check if the username and the user
certificates uploaded to the iDRAC6 have expired. The iDRAC6 trace logs
may provide important log messages regarding the errors; although the error
messages are sometimes intentionally ambiguous due to security concerns.
Unable to Log into iDRAC6 as an Active Directory User
If you cannot log into the iDRAC6 as an Active Directory user, try to log
into the iDRAC6 without enabling the Smart Card logon. If you have
enabled the CRL check, try the Active Directory logon without enabling
the CRL check. The iDRAC6 trace log should provide important messages
in case of CRL failure.
You also have the option of disabling the Smart Card Logon through the
local racadm using the following command:
racadm config -g
cfgSmartCard -o cfgSmartCardLogonEnable 0