Installation Manual

248 Configuring Intelligent Platform Management Interface
Configuring IPMI Using the RACADM CLI
1
Login to the remote system using any of the RACADM interfaces.
See "Using RACADM Remotely" on page 110.
2
Configure IPMI over LAN.
Open a command prompt, type the following command, and press
<Enter>:
racadm config -g cfgIpmiLan -o cfgIpmiLanEnable 1
NOTE: This setting determines the IPMI commands that can be executed
from the IPMI over LAN interface. For more information, see the IPMI 2.0
specifications.
a
Update the IPMI channel privileges.
At the command prompt, type the following command and press
<Enter>:
racadm config -g cfgIpmiLan -o
cfgIpmiLanPrivilegeLimit
<level>
where
<level>
is one of the following:
2
(User)
3
(Operator)
4
(Administrator)
For example, to set the IPMI LAN channel privilege to 2 (User), type
the following command:
racadm config -g cfgIpmiLan -o
cfgIpmiLanPrivilegeLimit 2
b
Set the IPMI LAN channel encryption key, if required.
NOTE: The iDRAC6 IPMI supports the RMCP+ protocol. See the IPMI 2.0
specifications for more information.
At the command prompt, type the following command and press
<Enter>:
racadm config -g cfgIpmiLan -o
cfgIpmiEncryptionKey
<key>