Installation Manual

Configuring Intelligent Platform Management Interface 249
where
<key>
is a 20-character encryption key in a valid
hexadecimal format.
3
Configure IPMI Serial over LAN (SOL).
At the command prompt, type the following command and press
<Enter>:
racadm config -g cfgIpmiSol -o cfgIpmiSolEnable 1
a
Update the IPMI SOL minimum privilege level.
NOTE: The IPMI SOL minimum privilege level determines the minimum
privilege required to activate IPMI SOL. For more information, see the IPMI 2.0
specification.
At the command prompt, type the following command and press
<Enter>:
racadm config -g cfgIpmiSol -o
cfgIpmiSolMinPrivilege
<level>
where
<level>
is one of the following:
2
(User)
3
(Operator)
4
(Administrator)
For example, to configure the IPMI privileges to 2 (User), type the
following command:
racadm config -g cfgIpmiSol -o
cfgIpmiSolMinPrivilege 2
b
Update the IPMI SOL baud rate.
NOTE: To redirect the serial console over LAN, ensure that the SOL baud rate
is identical to your managed system’s baud rate.
At the command prompt, type the following command and press
<Enter>:
racadm config -g cfgIpmiSol -o
cfgIpmiSolBaudRate
<baud_rate>
where
<baud_rate>
is 9600, 19200, 57600, or 115200 bps.