Installation Manual

Power Monitoring and Management 297
Power Off System
turns OFF the server’s power. This option is
disabled if the system is already powered OFF.
NMI (Non-Masking Interrupt)
generates an NMI to halt system
operation.
Graceful Shutdown
shuts down the system.
NOTE: Ensure that the shutdown option is configured for the operating
system before you perform a graceful shutdown using this option. If you use
this option without configuring it on the operating system, it reboots the
managed system instead of performing a shutdown operation.
Reset System (warm boot)
resets the system without powering off.
This option is disabled if the system is already powered off.
Power Cycle System (cold boot)
powers off and then reboots the
system. This option is disabled if the system is already powered OFF.
4
Click
Apply
. A dialog box is displayed requesting confirmation.
5
Click
OK
to perform the power management action you selected (for
example, cause the system to reset).
Using RACADM
Open a Telnet/SSH text console to the server, log in, and type:
racadm serveraction <action>
where <action> is powerup, powerdown, powercycle, hardreset, or
powerstatus.