Installation Manual

Recovering and Troubleshooting the Managed System 327
Remote Access Controller
NIC 4 Displays the Ethernet, iSCSI and the Virtual MAC
address(es) of the embedded Network Interface Controller
NIC 4 that uniquely identifies it in the network.
Table 19-4. RAC Information
Field Description
Name iDRAC6
Product
Information
Integrated Dell Remote Access Controller 6 – Enterprise
Date/Time Current time in the form:
Day Month DD HH:MM:SS YYYY
Example: Fri Jan 28 16:27:29 2011
Firmware Version iDRAC6 firmware version
Firmware Updated Date the firmware was last flashed in the form:
Day Month DD HH:MM:SS YYYY
Example: Sat Jan 29 2011 13:31:50
Hardware Version Remote Access Controller version
Table 19-3. Embedded NIC MAC Addresses
(continued)
Field Description
Virtual MAC Displays Virtual Media Access Control (MAC) addresses.
Virtual MAC data is obtained from hardware inventory, hence
the hardware Inventory needs to be collected once before
viewing the vMAC data.
Click System Inventory. The Inventory data is updated and
displayed on the System Inventory page. Click System
Details again. The Virtual MACs for each of the Embedded
LAN Ports is now displayed on the System Details page.
NOTE: The vMAC feature will be used by Dell Advanced
Infrastructure Manager (AIM) in the future releases. If Dell AIM
does not manage the server currently, then the Ethernet MAC
address and the Virtual MAC address are identical.