Installation Manual
58 Configuring the iDRAC6 Using the Web Interface
4
In the
Platform Event Filters List
table, do the following for the filter(s)
that you want to configure:
• Select one of the following actions:
• Reboot System
• Power Cycle System
• Power Off System
• No Action
•In the
Generate Alert
column, select the checkbox to enable alert
generation or clear the checkbox to disable alert generation for the
selected action.
NOTE: Generate Alert must be enabled for an alert to be sent to any valid,
configured destination (PET).
5
Click
Apply
. The settings are saved.
Configuring Platform Event Traps (PET)
NOTE: You must have Configure iDRAC permission to add or enable/disable an
SNMP alert. The following options will not be available if you do not have
Configure iDRAC permission.
1
Log in to the remote system using a supported Web browser.
2
Ensure that you have performed the procedures in "Configuring Platform
Event Filters (PEF)" on page 57.
3
Click
System
Alerts
Traps Settings
.
4
In the
IPv4 Destination List
or the
IPv6 Destination List
, do the following
for the
Destination Number
to configure the IPv4 or IPv6 SNMP alert
destination:
a
Select or clear the
State
checkbox. A selected checkbox indicates that
the IP address is enabled to receive the alerts. A clear checkbox
indicates that the IP address is disabled for receiving alerts.
b
In
Destination IPv4 Address
or
Destination IPv6 Address
, enter a
valid platform event trap destination IP address.