72 Configuring the iDRAC6 Using the Web Interface
Configuring iDRAC6 Services
NOTE: To modify these settings, you must have Configure iDRAC permission.
1
Click
iDRAC Settings
Network/Security
. Click the
Services
tab to
display the
Services
configuration page.
2
Configure the following services, as required:
Local Configuration — see Table 4-14.
Web server — see Table 4-15 for Web server settings.
SSH — see Table 4-16 for SSH settings.
Telnet — see Table 4-17 for Telnet settings.
Remote RACADM — see Table 4-18 for Remote RACADM settings.
SNMP Agent — see Table 4-19 for SNMP settings.
Automated System Recovery (ASR) Agent — see Table 4-20 for ASR
Agent settings.
3
Click
Apply
to apply the
Service
page settings.
Table 4-14. Local Configuration
Setting Description
Disable the iDRAC
Local Configuration
using option ROM
Disables local configuration of iDRAC using option ROM.
Option ROM resides in the BIOS and provides a user
interface engine that allows BMC and iDRAC
configuration. The option ROM prompts you to enter the
setup module by pressing <Ctrl+E>.
Disable the iDRAC
Local Configuration
using RACADM
Disables local configuration of iDRAC using local
RACADM.
Table 4-15. Web Server Settings
Setting Description
Enabled Enables or disables the iDRAC6 Web server. When
checked, the checkbox indicates that the Web server is
enabled. The default is enabled.