SPECIFICATION
S-240-5 S-240-7.5 S-240-12 S-240-15 S-240-24 S-240-30 S-240-48
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT VOLTAGE ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDTIME (Typ.)
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
ACCURRENT (Typ.)
INPUT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
SAFETY STANDARDS
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
5V 7.5V 12V 15V 24V 30V 48V
40A 30A 18A 15A 10A 8A 5A
0~40A 0~30A 0~18A 0~15A 0~10A 0~8A 0~5A
200W 225W 216W 225W 240W 240W 240W
150mVp-p 200mVp-p 150mVp-p 150mVp-p 180mVp-p 180mVp-p 240mVp-p
4.5~5.8V
6~9V
10~14V 12~18V 20~28V 27~33V 41~56V
2.0% 2.0% 1.0% 1.0% 1.0% 1.0% 1.0%
0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 1.0%
1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 1.0%
1000ms,20msatfullload
36msatfullload
47~63Hz
78% 80% 82% 83% 84% 85% 87%
5A/115VAC2.5A/230VAC
15A/115VAC30A/230VAC
<2mA /240VAC
105~135% ratedoutputpower
6~7V 9.4~10.9V 14.4~16.8V 18.5~21.5V 31.2~36V 34.5~40.5V 57.6~67.2V
Protectiontype:Hiccupmode,recoversautomaticallyafterfaultconditionisremoved.
Protectiontype: Hiccupmode,recoversautomaticallyafterfaultconditionisremoved.
RT1 40 FANON, 35 FANOFF, 70 outputshutdown
-10~+60 (Refertooutputloadderatingcurve)
20~90%RHnon-condensing
-20~+85 ,10~95%RH
0.03%/ (0~50 )
10~500Hz,2G10min./1cycle,60min.eachalongX, Y,Zaxes
179.3Khrsmin.MIL-HDBK-217F(25 )
190*93*65mm(L*W*H)
1.2Kg;12pcs/15.3Kg/0.78CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
FileName:S-240-SPEC2005-09-13
88~132VAC/176~264VACautoswitch248~370VDC
FUNCTION
FANCONTROL,O.T.P.
UL60950-1, TUVEN60950-1 Approved(7.5VDesignreferto TUVEN60950-1)
HARMONICCURRENT
EMSIMMUNITY
CompliancetoEN55022(CISPR22)ClassB
Complianceto EN61000-3-2,-3
Complianceto EN61000-4-2,3,4,5,6,8,11;ENV50204,Lightindustrylevel,criteria A
240WSingleOutputSwitchingPowerSupply
Auto switched 88 ~ 264VAC input
Built-in passive PFC choke
Protections:Short circuit/Over load/Over voltage/Over temperature
Forced air cooling by built-in DC fan
Built-in cooling Fan ON-OFF control
LED indicator for power on
Fixed switching frequency at 75KHz
2 years warranty
Features :
S- 2 40 se r ie s
ENVIRONMENT
PROTECTION
EMICONDUCTION&RADIATION
SAFETY &
EMC
(Note4)
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC