Installation Guide Part 2
Table Of Contents
- Technician Operations
- Getting Started
- Testing Alarms
- Configuring the Entry/Exit Delay Periods
- Configuring the Alarm Transmission Delay
- Configuring the Swinger Shutdown Feature
- Resetting the TouchScreen to Factory Defaults
- Checking for New Firmware Updates for the TouchScreen
- Enabling Fire Alarm Verification
- Managing the Physical Devices in the Security System
- Managing Sensors & Zones
- Appendix A: General Concepts of the Security System
- Appendix B: TouchScreen Placement Options
- Appendix C: General Info for Sensor Placement
- Appendix D: Installer Quick Reference (SIA)
Managing Sensors & Zones
65
To force default a door/window sensor:
1. Find the locking mechanism on the bottom of the
SMCDW01-Z.
2. Holding the SMCDW01-Z in one hand, carefully insert the
tip of a screwdriver into the locking mechanism.
3. Push lightly upwards from the back of the SMCDW01-Z until the back plate
separates from the sensor.
4. Remove the battery.
5. While pressing and holding the tamper switch, insert the battery into the
SMCDW01-Z, with the positive (+) end oriented towards the tamper
switch. The front panel LED goes ON.
6. After 1 second, release the tamper switch. The LED blinks green.
7. Replace the SMCDW01-Z back plate.
To force default a glass break detector:
1. Remove the cover from the glass break detector.
2. Remove the battery.
3. While pressing and holding the tamper switch, insert the battery into the glass break detector.
The front panel LED goes ON.