MSDS

®
TechniSoil SafeTy DaTa SheeT
TechniSoil NanoPave® Concrete Sealer
3
cr081913
TechniSoil Global Inc - NanoPave® Concrete Sealer - Safety Data Sheet
8. EXPOSURE CONTROLS /
PERSONAL PROTECTION
(CONTINUED)
RESPIRATORY PROTECTION: A respiratory protection program meeting OSHA 1910.134
and ANSI Z88.2 requirements or equivalent must be followed whenever workplace conditions
warrant a respirator’s use. None required if airborne concentrations are maintained below
the exposure limit listed in Exposure Limit Information. For airborne concentrations up to 10
times the exposure limit, wear a properly fitted NIOSH approved (or equivalent) half-mask,
air-purifying respirator. Air-purifying respirators should be equipped with NIOSH approved
(or equivalent) N95 filters. If oil mist is present, use R95 or P95 filters.
PROTECTIVE MEASURES: Facilities storing or utilizing this material should be equipped
with an eyewash facility.
ENGINEERING MEASURES: Use local exhaust ventilation with a minimum capture velocity of
100 ft/min. (0.5 m/sec.) at the point of vapor evolution. Refer to the current edition of Industri-
al Ventilation: A Manual of Recommended Practice published by the American Conference of
Governmental Industrial Hygienists for information on the design, installation, use, and main-
tenance of exhaust systems.
9. PHYSICAL AND
CHEMICAL PROPERTIES
APPEARANCE
For
m: liquid
Colour: white milky
Odor: acrylic
COMPONENT VALUE
pH
6.0 - 8.0
Boiling point/boiling range 100 °C ( 212.00 °F) Water
Melting point/range 0 °C ( 32 °F)
Flash point Noncombustible
Lower explosion limit Not Applicable
Upper explosion limit Not Applicable
Vapour pressure 17.0 mmHg at 20 °C
(68.00 °F) Water
Relative vapour density <1.0 Water
Water solubility Miscible
Relative density 1.00 - 1.20
Viscosity, dynamic
80 - 400 mPa.s maximum
Evaporation rate <1.00 Water
Percent volatility
37 - 39 % Water
Volatile organic compounds
(VOC)
<= 5 g/L
NOTE: The physical data presented above are typical values and
should not be construed as a specification.
10. STABILITY & REACTIVITY Hazardous reactions
Materials to avoid
Polymerization
None known. Stable
There are no known materials which are
incompatible with this product.
Product will not undergo polymerization.