The following settings must be programmed for each mode in a Trunked (P25 9600, SmartNet or SMARTZONE)
Radio:
System Type TG Strapping
System ID Zone
Individual ID Scan List
Coverage Type Scan Type
Affiliation Type Interconnect
Control Channel 1 Phone Display Format
Control Channel 2 Private Call
Talkgroup 1 Private Call Type
Talkgroup 2 Private Call Operation
The function keys along with the rest of the key pad, revert to normal number keys during transmit and when
NUM LOCK is selected by pressing the rotary knob.
2.7 MUP AND MDN KEYS
These keys provide the same function as the rotary knob does when it is set to CHAN. This equates to the 16
position rotary knob on the portable. When one of these keys is pressed, the function of the rotary knob is
automatically set to CHAN.
2.8 UP AND DN KEYS
The keys provide the same function as the left and right arrow keys on the portable. The UP key equates to the
right arrow key. These keys are used for a variety of functions but in the normal mode they are used to scroll
through the soft key menus.
2.9 BRT AND DIM KEYS
Use these keys to dim or brighten the display. The radio powers up at full brightness for normal use but can be
dimmed for night operations.
2.10 ESW KEY
The ESW key provides the function of the concentric or ergo switch on the portable. The switch has two
conditions which are represented by O’ and . Pressing the ESW key toggles the condition back and forth.
The condition is displayed at the bottom of the display, second character from the right. The ergo switch
condition is saved when the unit is turned off. There are separate conditions for each band installed. The ESW
key can be programmed with the CPS™ to a variety of functions such as low power, scan, channel, and secure
mode.
2.11 TSW KEY
The TSW key provides the function of the toggle switch on the portable. The switch has three conditions
which are represented by A’, ‘B and C. Pressing the TSW key toggles the condition A,B,C,A,B, etc. The
condition is displayed at the bottom of the display, last character on the right. The toggle switch condition is
saved when the unit is turned off. There are separate conditions for each band installed. The TSW key can be
programmed with the CPS™ to a variety of functions such as low power, scan, channel, and secure mode.