MYWELLNESS KIOSK USER MANUAL
The User Manual was written in the Manufacturer’s original language and then translated into the language of the country of use. It is an integral part of the product kit. Technogym reserves the right to modify its products and documentation at any time and without notice. Technogym s.p.a. will accept responsibility for the product only if the following precautions are observed: - The product is used in compliance with its specifications. - Every part of the User Manual has been carefully read.
Contents Safety warnings ......................................................................................................................................4 Description of the product ................................................................................................................6 Technical characteristics ...................................................................................................................8 Mains connection and switching on .................................
Safety warnings Please read all instructions before using the product. These were written to ensure the safety of the user and to protect the product. When using an electrical appliance, basic precautions should be always followed, including those listed below. WARNING. To reduce the risk of electric shock, always remove the plug from the electrical socket immediately after using and before cleaning or performing any maintenance procedures. WARNING.
Keep the product in good working condition. If you see signs of wear, contact Technogym technical support service. Do not attempt any maintenance work on the product other than the operations described in the user manual. The installation, maintenance and setting operations must be carried out by qualified Technogym staff or persons authorised by Technogym. The electrical system must conform to the standards and legal requirements in the country of use. Do not place anything on the screen.
Description of the product A. 22” full HD touch screen B. Technogym key socket C. USB port D. NFC sensor for the Mywellness band and smartphone E. Wireless charger F. Network or LAN socket for the Ethernet connection G. Socket for the HDMI 1.4 connector (up to 4k) H. USB service ports K. Microphone input socket. The microphone can be connected with a 6 mm jack, or a 3-pin XLR connector. L. Audio stereo output for speakers. RCA connectors The device is compatible with Bluetooth® 5.
Wireless charger Use a smartphone with Qi certification. Place the smartphone correctly in the battery charger. The smartphone may not charge correctly if it is not positioned correctly on the charging surface. Depending on the position of the wireless battery charger coil, the smartphone may not charge correctly. The wireless battery charger is not compatible with quick charge. Wireless charging may not function correctly if the smartphone has a thick case.
Technical characteristics Power supply 100÷240 Vac 50/60 Hz 2.0 - 1.0A Fuse 4A - 250V Littelfuse: 216004; Cooper Bussmann: S501-4-R; Schurter: 0001.1010, 0034.1522; Bel Fuse: 5HF 4-R, 5SF 4-R Electric class I Risk class IIa Protection rating IP20 Operating temperature Between +5 and +30°C Device weight 24,5 kg The Mywellness Kiosk is a commercial device intended for residential and professional use indoors.
FCC Regulatory Notices This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1 - the device may not cause harmful interference; and 2 - the device must accept any interference received, including interference that may cause undesired operation. FCC label NOTE. Changes or modifications made to this equipment not expressly approved by the manufacturer may void the FCC authorization to operate this equipment. NOTE.
Mains connection and switching on M. Main switch. Turns the device power supply voltage on and off. N. Fuse. Protects the electrical components of the device.
Before connecting the device to the mains power supply, ensure that the electrical system specifications comply with current regulations. Check that the mains voltage corresponds to what is indicated on the product identification label. Plug the power cable into the product socket first and then into the wall socket. When plugging it in, the switch must be in the 0 position, that is the product must be off.
Lifting and moving the product The product has two mono-directional wheels. To move it, grasp the storage compartment and turn the product towards you until the wheels are firmly on the ground. Do not use the screen as a gripping point for movement. WARNINGS. Move the product very carefully, because it could become unstable and tip over. Disconnect all the cables from the sockets before moving the product.
Routine maintenance Routing maintenance involves correctly cleaning all parts of the machine. Use non-aggressive solvents. Before pouring liquid detergents, turn off the product and disconnect the power supply cable from the socket. The safety of the product is assured only if it is carefully inspected every two weeks for any signs of damage and/or wear. Replace defective and worn components immediately, or alternatively remove the product from service.
Replacing the fuse DANGER. Turn off the product before replacing the fuse. Turn the switch to 0 and disconnect the power supply plug from the container. Press the lever to extract the fuse holder (P). Replace the burnt fuse with the new one that is provided (4A (F) 250V). Refit the fuse holder in its seat, making sure it snaps in correctly. The product is supplied with 2 fuses.
Manufacturer and product identification A. Manufacturer’s name and address B. Manufacturer location C. Description of the product D. Electrical specifications E. Consultation of user manual required F. Serial number and date of manufacture G. Product model The values shown in the drawing are indicative. check the label on the product for the correct information.
Technical Service When you contact the Technogym Technical Support Service, you must give the following information: - product model (G) - date of purchase - serial number (F) - a precise description of the problem. Any work on the product by persons unauthorised by Technogym will invalidate the warranty. Technogym S.p.a. via Calcinaro 2861, 47521 Cesena (FC) - Italy G Made in Italy MYWELLNESS KIOSK FCCID: VPYLBEE5HY1MW, 2ANP7EGG190098, 2ARDN0615E, O6R3153 100 - 240 Vac 2.0 - 1.
Storing and disposing of the product If not used for a long period of time, we recommend storing the product: - in a clean and dry place, covered with a cloth to protect it from dust; - at a room temperature between -10°C and +70°C and relative humidity between 20% and 90%. During any long periods when it is not used, disconnect the power supply cable to turn it off. Check that the product does not create any type of hazard; do not let children play with the product.
Disposing of the battery The product contains a lithium battery. The battery is made of non-recyclable materials. Do not dispose of the battery in the environment. A The battery must be disposed of in compliance with the local regulations. Contact firms specialised in urban and environmental hygiene. Observe the following instructions to remove the battery safely. Remove the cover (A) and the tab (B). Remove the screws (C). Release the cover (D) from its seat.
Turn the cover (D) and place it on the storage compartment. Remove the connectors (E). Unscrew the screws (F). Remove the battery (G).
Mywellness Kiosk_en 0SM01173AB July 2022