Spec Sheet

TecMate North America TecMate International
1100 Invicta Drive #22,
Oakville, ON L6H 2K9, Canada
Sint-Truidensesteenweg 252
B-3300 Tienen, Belgium
www.tecmate.com www.tecmate-int.com
How it works
1. Safety check: OptiMate 3+ will only activate if connected to a battery that has at least 2V of charge.
2. Desulfation and recovery: if the battery’s resistance is abnormally high due to sulfation, a voltage of up to 20V is
automatically applied to overcome this to recover very flat or neglected batteries (disconnected from the vehicle)
until they are able to accept the normal charge program.
3. Bulk charge: a constant current of 0.6A brings the battery close to full charge.
4. Charge verification: as soon as the rising resistance causes the charge voltage to reach 14.3V, the voltage is limited
at 13.6V for 30 minutes while the circuit monitors the actual voltage and the current absorbed by the battery. If within
30 minutes the achieved charge is less than optimal, the program goes back to bulk charge and the process repeats.
5. Charge retention test: when the charger confirms that an optimal charge has been achieved, the first check for
battery (and connected system) power leakage begins. Depending on the voltage retained during 30 minutes, an
“OK” (green LED) or “not OK” (red LED) test result is displayed. These 30 minute test periods repeat hourly until the
OptiMate 3+ is disconnected, so that the battery status indication is continually updated.
6. Charge maintenance: during alternate 30 minute periods, at a float limit of 13.6V the battery is offered charge
current (up to the maximum) it needs to sustain it against any small connected loads or power leakage and against
natural self-discharge.
OptiMate 3 +can stay connected to the battery indefinitely and the battery will be safe & 100% charged.
(Standard filler cap batteries need their liquid level checked regularly during long term connection.)
Technical Specifi cations
Use on the following 12V lead-acid batteries:
AGM/MF, Standard, & GEL batteries
Size: 2Ah to 45Ah rated capacity
Program control 5 stages, fully automatic
Reverse drain current less than 0.5mA
Output current (bulk charge) 0.6A
Automatic desulfation YES
Charge time limit safe to leave connected for months at a time
Maintain / test cycles 30 min/30 min (alternating hourly)
Charge retention test monitors during 30min no charge intervals
Size 7 ½ x 3 x 2 ¼ inches (190 x 75 x 56 mm)
Weight (packaging) 1.7lbs (2.4lbs) – 0.8kg (1.1kg)
Wall mounting easy direct wall mounting
Input cable length 6ft (2m)
Output cable length 6ft (2m)
Accessories Included SAE-71 weatherproof fused ringlet set
SAE-74 clamps set for bench charging
Operation temperature range From -20°C / -4F to 40°C/104F
Warranty 3 years
copyright © 2009 Tecmate International - TM151-PL1-100319_EN