Figure 51: Mounting Vanishing DW Sensor
Transmitter—Window
Select the location where the vanishing sensor is to be located. Mount the transmitter on
the window jam near the top of the section of the window to be protected. The integral
magnet should be mounted on the window, within ½ inch of the transmitter with the
notch on the magnet aligned with the middle notch on the transmitter.
Mounting the Transmitter
Step
Action
1.
Use the base of the sensor as a template and mark the mounting holes with a
pencil.
2.
Drill the holes for the screws, 5/16” drill size.
3.
Mount the base to the door jam with the screws provided
For doors that open on the left hand side, the round battery cavity in the
base should be at top when the base is mounted to the door jam.
For doors that open on the right hand side, the round battery cavity in the
base should be at the bottom when the base is mounted to the door jam.
4.
Carefully replace the sensor on the base by aligning the tamper switch with the
plastic tamper tab and snap the cover down on the base.