6.2.11.7 Specifications—Temperature/Flood Sensor
Specifications
Operating Temperature
32° to 120° F (0° to 49° C)
Operating Rel. Humidity
5 to 95%, non-condensing
Operating Frequency
433.92MHz
Battery Type
CR 2 3-volt lithium battery
Projected Battery Life
7 years (based on 20 activations per day)
Installation Kit
Double-faced mounting tape
Two (2) 6x32 flat head screws
6.2.12 Garage Door Tilt Sensor (Not Evaluated by UL)
The AT&T model number SW-ATT-TILT is a fully supervised tamper protected Garage
Door Sensor that will monitor the opening and closing of a garage door installed in the
DLS. It is designed to be mounted on the top section of a sectional garage door. Once
the garage door is opened to a minimum angle of 45 degrees the sensor will initiate an
alarm (or garage door open) condition. The sensor will also send a restore (or garage
door closed) condition when the tamper switch is returned to a position where the angle
is less than 45 degrees. If the case of the SW-ATT-TILT is removed for any reason, the
radio transmitter will send a tamper alert to the DLC. Should the battery voltage drop
below a prescribed level, the SW-ATT-TILT will send a low battery report indicating that
the battery requires changing.
6.2.12.1 Discovering and Registering the Tilt Garage Door Sensor
Follow these steps to discover and register the Garage Door Tilt Sensor:
Step
Action
1.
Place the DLC into Discovery Mode in DLD.
2.
Make the Tilt Garage Door Sensor discoverable by inserting the battery.
Alternate Method: Remove the cover and it will activate the tamper switch.
3.
Confirm that the Tilt Garage Door Sensor has been discovered in DLD.
4.
Label the Tilt Garage Door Sensor in DLD.