Operation Manual
IRREGULAR FLAME AND/OR SOOT AND/OR SMELLS
E The combustion chamber D has not been positioned correctly.
Use the handle E to put it level, until you can easily slide it slightly to the left
and to the right and the chamber is level.
E You are using fuel which is past its ‘use by’ date.
Start every heating season with fresh fuel.
E You are using the incorrect type of fuel.
Refer to THE RIGHT FUEL (See Section ’What you need to know in advance’).
E Dust has gathered in the lower part of the heater.
Contact your dealer.
E The wick height is not correct.
Contact your dealer.
THE HEATER SLOWLY EXTINGUISHES
E The removable tank is empty.
See Section B.
E The lower reservoir is contaminated by moist.
Contact your dealer.
E The wick has hardened on the upper side.
Burn the heater until all fuel is used (Section G). Use the right fuel.
E You are using fuel which is past its ‘use by’ date.
Start every heating season with fresh fuel.
THE HEATER REMAINS BURNING LOW
E Wick position too low.
Contact your dealer.
E Before you refilled the tank, the heater had burnt up almost all the fuel.
After having refilled and replaced the removable tank, wait for 30 minutes
before igniting the heater.
E You are using the incorrect type of fuel.
Refer to THE RIGHT FUEL (See Section ’What you need to know in advance’).
E The room is insufficiently ventilated.
Leave a window or a door wide open for a while.
THE HEATER IS BURNING TOO HIGH
E You are using an incorrect, too volatile type of fuel.
Refer to THE RIGHT FUEL (See Section ’What you need to know in advance’).
E Wick position too high.
Contact your dealer.
G MAINTENANCE
Your heater needs hardly any maintenance. It is, however, important that you
remove dust and stains in time with a damp cloth, because otherwise these may
cause stains that are hard to remove. Under normal conditions, only three
components are subject to wear:
4
56