Operation Manual
4
121
M T
ECHNICAL DATA
* EN 14511
** To be used as indication
*** Moisture removal at 32°C, 80% RH
Waste electrical products should not be disposed with household waste. Please recycle where facili-
ties exist. Check with your local authority or retailer for recycling advice.
Environmental information: This equipment contains fluorinated greenhouse gases covered by the Kyoto
Protocol. It should only be serviced or dismantled by professional trained personnel.
This equipment contains R407c refrigerant in the amount as stated in the table above. Do not vent R407c
into atmosphere: R407c, is a fluorinated greenhouse gas with a Global W
arming Potential (GWP) = 1653
TSC 126
Type air-conditioner Wall mounted split
Cooling capacity (max) * W 2600
EE Class* D
E
ER* 2.6
Heating capacity (max) * W 3100
Heating performance
D
COP* 2.87
Dehumidifying capacity ** L / 24h 24
Power consumption cooling kW 1
Power consumption heating kW 1.1
Power supply V / Hz / Ph 220 - 240 / 50 / 1
Current (nom.) cooling / heating A 4.6 / 4.7
Max. Current A 7
Air flow **
m
3
/h
450/400/350
For rooms up to**
m
3
65 - 90
Compressor type Rotary
Fan speeds 3
Thermostatic range ºC 17 - 30
Operating range ºC 10 - 40
Controls manual / mechanic / electronic
Electronic remote
Remote control Yes / No Y
Air filter type(s) Screen, Active carbon
Refrigerant type / charge r / gr R407c / 850
Pressure suction / discharge bar 5 / 18
Dimensions indoor unit (w x h x d) mm 750x250x188
Dimensions outdoor unit (w x h x d) mm 830X365X365
Net weight indoor unit kg 11.5
Net weight outdoor unit kg 29
Gross weight indoor unit kg 15
Gross weight outdoor unit kg 31
Sound pressure level indoor unit dB(A) 30 - 36
Sound pressure level outdoor unit dB(A) 50
Unit protection indoor IP IP20
Unit protection outdoor IP IP24
Fuse rating T3.15A / 250V
Model
man_TSC126_uk.qxd 10-05-2007 15:41 Pagina 121