Performance Data Sheet

Sept. 4, 2014
Revision: REL
Celseon® Air Cooled Condensing Unit
Model: AJA7480ZNACJ
BoM: 2G1010-79XP R-404a 1 HP
Model
Dimensions, inches
Line Connection*
Pumpdown
Air
Oil Ch
Gr. Wt.
L
W
CH
Suction
Liquid
90 °F 90%
SCFM
Oz.
Lbs.
AJA7480ZNACJ
24.0
17.5
11.8
5/8” S
3/8” S
6.1 lbs
270
26
78
* F = Flare, S = Solder, RF or RS = Rotolock with Flare or Solder Connections, C = Compression Fitting
Factory charge: 20 PSIG Nitrogen MUST BE EVACUATED
Ambient Temperatures
Evaporator T, 80°F 90°F 100°F 110°F
°F
PSIG
BTUH
Watts
Cond T
BTUH
Watts
Cond T
BTUH
Watts
Cond T
BTUH
Watts
Cond T
-10
24.3
5243
1291
104
4586
1293
112
3921
1265
120
3284
1244
128
-5 28.9 5892 1406 107 5181 1415 115 4449 1389 123 3779 1357 131
0
33.4
6524
1519
111
5762
1539
118
4963
1518
126
4251
1487
133
5
39.0
7140
1637
114
6328
1667
121
5463
1651
129
4701
1636
136
10 43.9 7739 1759 117 6880 1798 125 5950 1788 132 5129 1803 139
15
49.8
8322
1886
121
7417
1932
128
6424
1930
135
5535
1988
142
20
56.1
8888
2018
124
7940
2070
131
6883
2076
138
---
---
---
25 62.9 9439 2155 127 8448 2210 134 7329 2226 141 --- --- ---
32
72.5
10181
2354
132
9136
2412
139
---
---
---
---
---
---
35
77.9
10490
2443
134
9422
2501
141
---
---
---
---
---
---
60 Hz Performance
Return gas temp. 40°F, 5°F sub cooling

Summary of content (3 pages)