Performance Data Sheet

Performance Data Sheet
AWA2440ZXT
General Information
Model AWA2440ZXT Refrigerant R-404A
Test Condition ARI Performance Test Voltage 230V 3~ 60HZ
Return Gas 4.4°C (40°F) RETURN GAS Motor Type 3PH
Performance Information
Condensing Temperature (°F)
Evap Temp (°F)
80 90 100 110 120 130 140
Btu/h 1910 1590 1270 951 634 320 9.42
Watts 939 827 715 603 490 378 265
Amps 3.19 3.05 2.92 2.78 2.65 2.51 2.37
-40
Lb/h 36.3 28.7 20.9 13.1 5.02
Btu/h 2610 2170 1740 1310 877 451 26.6
Watts 983 884 784 684 584 483 382
Amps 3.31 3.19 3.07 2.94 2.81 2.69 2.56
-35
Lb/h 50.3 41.5 32.5 23.4 14.1 4.67
Btu/h 3420 2870 2320 1770 1230 688 149
Watts 1040 949 861 773 684 596 507
Amps 3.45 3.33 3.22 3.11 2.99 2.87 2.75
-30
Lb/h 65.7 55.6 45.5 35.1 24.7 14.0 3.10
Btu/h 4330 3670 3000 2340 1680 1030 370
Watts 1100 1020 944 868 791 714 637
Amps 3.59 3.49 3.38 3.28 3.17 3.07 2.96
-25
Lb/h 82.5 71.2 59.9 48.4 36.7 24.8 12.7
Btu/h 5350 4570 3790 3010 2230 1460 684
Watts 1160 1100 1030 969 903 838 771
Amps 3.74 3.65 3.56 3.46 3.37 3.28 3.18
-20
Lb/h 101 88.4 75.8 63.1 50.3 37.2 24.0
Btu/h 6470 5570 4670 3770 2870 1980 1090
Watts 1240 1180 1130 1070 1020 965 910
Amps 3.90 3.82 3.74 3.66 3.58 3.50 3.41
-15
Lb/h 121 107 93.4 79.5 65.5 51.3 36.9
Btu/h 7680 6660 5640 4620 3600 2580 1570
Watts 1310 1270 1230 1180 1140 1100 1050
Amps 4.07 4.01 3.94 3.87 3.80 3.73 3.66
-10
Lb/h 142 127 113 97.6 82.5 67.1 51.6
Btu/h 8980 7830 6690 5550 4400 3260 2120
Watts 1390 1360 1330 1300 1260 1230 1190
Amps 4.26 4.21 4.15 4.09 4.04 3.98 3.92
-5
Lb/h 165 150 134 118 101 84.8 68.1

Summary of content (2 pages)