IC18 SPREADER JOB COMPUTER U S E R Software version 1.
ISOBUS Job Computer : IC18 Spreader NA COPYRIGHTS © 2011 TeeJet Technologies. All rights reserved. No part of this document or the computer programs described in it may be reproduced, copied, photocopied, translated, or reduced in any form or by any means, electronic or machine readable, recording or otherwise, without prior written consent from TeeJet Technologies.
ISOBUS Job Computer : IC18 Spreader NA Table of Contents CHAPTER 1– PRODUCT OVERVIEW OPTIONAL SYSTEM COMPONENTS 1 1 CONFIGURATIONS 2 CHAPTER 2 – GETTING STARTED 3 START UP 3 CALCULATION MODE 4 PAGE LAYOUT AND NAVIGATION 5 OVERVIEW Home Screen................................................................................................................................ 5 Transport Mode...........................................................................................................
ISOBUS Job Computer : IC18 Spreader NA Total Counters.................................................................................................................................................17 Area Counter.................................................................................................................... 17 Amount Counter................................................................................................................ 17 Time Counter.....................................
ISOBUS Job Computer : IC18 Spreader NA COMMUNICATION 29 HELP 30 Diagnostic........................................................................................................................................................31 Test Input.................................................................................................................................... 31 Test Output..............................................................................................................................
ISOBUS Job Computer : IC18 Spreader NA CHAPTER 1– PRODUCT OVERVIEW GETTING STARTED OVERVIEW Congratulations on the purchase of your new IC18 Spreader ECU built on the ISOBUS architecture. When used within the guidelines of the this manual, the IC18 controller will be a reliable application tool. This manual covers the North America functions of the IC18 ECU. For European functions, see manual number 98-05271.
ISOBUS Job Computer : IC18 Spreader NA CONFIGURATIONS The following diagram is reflective of typical IC18 Job Computer configuration. Due to the variety of possible configurations, this should be used for reference purposes only.
ISOBUS Job Computer : IC18 Spreader NA CHAPTER 2 – GETTING STARTED • A firm touch is required when selecting a screen icon. • Settings are NOT automatically saved when selected. The ACCEPT KEY must be selected to save the setting. Select the ESCAPE KEY to escape without saving settings and return to the previous menu. • The console needs to be cycled off and back on when changing or attaching equipment to the system.
ISOBUS Job Computer : IC18 Spreader NA CALCULATION MODE The IC18 job computer is programed to calculate calibrations based on North American or European methods. ◄North America – Gate Height is calculated into the product application and calibrations will be based on pulses per volume. ◄European – Gate Height is NOT calculated into the product application and calibrations will be based on volume per pulse.
ISOBUS Job Computer : IC18 Spreader NA PAGE LAYOUT AND NAVIGATION The Master Screen gives access to the systems currently available on your VT. From the Master Screen, the Home Screen gives access to the IC18’s available functions. Home Screen The Home Screen gives access to the IC18’s available functions: Operation Mode, Transport Mode and Main Setup.
ISOBUS Job Computer : IC18 Spreader NA Operation Mode Information on the Operation screen will vary depending on the parameters set by the user and the OEM. Figure 2-6: Operation Mode Count Number Applied Volume Cnt Alert Warning 1 Applied Area 298.2 ton 0.0 Speed/Application Information 500 lb/mi Remaining Bed Contents 1.14 ac lb/ac 1 3 11 Home Key Information Key Start/Stop Key Application On/Off Indication Rolr RPM Roller RPM OVERVIEW GETTING STARTED SETUP OPERATION APPENDIX 6 www.
ISOBUS Job Computer : IC18 Spreader NA Main Setup Mode The main setup menu contains six options. Each of these options either directly access settings or additional menus.
ISOBUS Job Computer : IC18 Spreader NA Main Setup Menu Icons and Section Overviews Figure 2-8: Enter Selection Screens Selection Slide Bar with Decrease One Selection and Increase One Selection Arrows Accept Key Escape Key Number Pad Close Number Pad Key Range Maximum Range Minimum Zoom In Key OVERVIEW Zoom Out Key Open Number Pad Key GETTING STARTED Available Selections SETUP Up One Selection Accept Key Escape Key OPERATION Down One Selection APPENDIX 8 www.teejet.
ISOBUS Job Computer : IC18 Spreader NA Description Accept Key Accepts the new selection Close Number Pad Key Minimizes the number pad Decrease One Selection Arrow Decreases the setting Down One Selection Arrow Highlights the selection below Escape Key Escapes without saving changes Increase One Selection Arrow Increases the setting Number Pad Use the numbers to set the selection value Open Number Pad Key Maximizes the number pad Selection Displays the current or new selection Slider Slid
ISOBUS Job Computer : IC18 Spreader NA OVERVIEW GETTING STARTED SETUP OPERATION APPENDIX 10 www.teejet.
ISOBUS Job Computer : IC18 Spreader NA CHAPTER 3 – MAIN SETUP Main Setup Mode configures the Counters, Job Parameters, Machine, User Interface, Communication and Help options. NOTE: The menu structure on your display might vary from the one displayed in this User Manual depending on the virtual terminal being used. CALCULATION MODE GETTING STARTED OVERVIEW The IC18 job computer is programed to calculate calibrations based on North American or European methods.
ISOBUS Job Computer : IC18 Spreader NA MAIN SETUP MODE OVERVIEW Figure 3-2: Main Setup Screen Home Key Back One Screen Forward One Screen Up One Option Down One Option Master Screen Key MAIN SETUP MODE MENU STRUCTURE | Counters (pages 15-18) | | | | | Job Parameters (pages 19-20) Machine (pages 21-28) User Interface (pages 28) Communication (pages 29) Help (pages 30-33) OVERVIEW Trip Filling Diagnostic Campaign Operation About Total Implement parameters GETTING STARTED Export Counters
ISOBUS Job Computer : IC18 Spreader NA 98-05173 R1 US 13 GETTING STARTED SETUP OPERATION APPENDIX NOTE: Settings are NOT automatically saved when selected. The ACCEPT KEY must be selected to save the setting. Select the ESCAPE KEY to escape without saving settings and return to the previous menu. To access the Main Setup screens: 1. Select IC18 JOB SPREADER KEY from the Master Screen. 2. Select MAIN SETUP SCREEN KEY from the Home Screen. 3.
ISOBUS Job Computer : IC18 Spreader NA Master Screen The Master Screen gives access to the systems currently available on your VT. • To view the Master Screen options, select MASTER SCREEN KEY in bottom right corner of any screen. Figure 3-3: Master Screen Master Screen Key on Main Setup Screen OVERVIEW Home Screen GETTING STARTED The Home Screen gives access to the IC18’s available functions: Operation Mode, Transport Mode and Main Setup.
ISOBUS Job Computer : IC18 Spreader NA COUNTERS The Counters Menu provides an overview of various system counters including Trip Counters, Campaign Counters and Total Counters. From this screen one can also Export Counters. | Counters | Job Parameters MAIN SETUP MENU | Machine | User Interface | Communication | Help Trip Campaign Total Export Counters OVERVIEW 1. From the Main Setup Screen , select COUNTERS. Figure 3-5: Counters 2.
ISOBUS Job Computer : IC18 Spreader NA Trip Counters Trip Counters displays information regarding area, distance, time and amount applied. The trip that is active is displayed/active on the Operations Screen. Figure 3-6: Trip Counters Menu Active Trip Counter One of up to ten (10) Active Trip Counters can be selected to view the desired trip information. The trip that is “active” is displayed/active on the Operation Screen. • To select the Active Trip Counter, use the number pad or slide bar.
ISOBUS Job Computer : IC18 Spreader NA Campaign Counters Campaign Counters display information regarding area, Figure 3-8: Campaign Counters amount applied and time for all trips. • To clear the Campaign Counters, select TRASH CAN KEY . A confirmation screen will be displayed. Area Counter Displays total applied area for all trips. Amount Counter Displays total amount of material applied during all trips.
ISOBUS Job Computer : IC18 Spreader NA Export Counters Export Counters allows counter information to be exported Figure 3-11: Export Counters in HTML or CSV format. HTML files can be viewed from an internet browser. CSV files can be viewed as Excel sheets. • To export a HTML file, select HTML KEY .A confirmation screen will be displayed. • To export a CSV file, select CSV KEY .A confirmation screen will be displayed. For data transfer, an optional cable is required.
ISOBUS Job Computer : IC18 Spreader NA JOB PARAMETERS Job Parameters configures application settings. Options include Active Trip Counter, Application Rate, Tonnage, Gate Height and Density. | Counters MAIN SETUP MODE MENU STRUCTURE | Job Parameters 1. From the Main Setup Screen PARAMETERS. | Machine , select JOB | User Interface | Communication | Help Figure 3-13: Job Parameters NOTE: Settings are NOT automatically saved when selected. The ACCEPT KEY must be selected to save the setting.
ISOBUS Job Computer : IC18 Spreader NA Tonnage Tonnage converts pounds/kilograms to tons. It is used when the application rate exceeds the number of digits allowed on the screen display. • To select the tonnage mode, select an option from the drop down menu or use the UP/DOWN ARROWS to highlight the option. Gate Height Gate Height is the height of the gate opening. Range is 0.0 - 35.0 in / 0.0 - 99.9 cm. • To select the gate height, use the number pad or slide bar.
ISOBUS Job Computer : IC18 Spreader NA MACHINE Machine configures machine settings. Options include Filling, Operation, Implement Parameters, Calibrations, Alarm Configurations and OEM.
ISOBUS Job Computer : IC18 Spreader NA Filling Filling establishes the amount of material remaining in the bed. NOTE: The size of the tank is established in the OEM menu. This is the number that will repopulate when the Full Bed Key is pressed. Figure 3-16: Filling Amount Remaining Actual Content displays the current volume of content in the tank.The volume can be manually adjusted. • To adjust the volume, use the number pad or slide bar.
ISOBUS Job Computer : IC18 Spreader NA Implement Parameters Implement Parameters establishes the the Working Width, Figure 3-18: Implement parameters Fast Empty Bed RPM and Master Switch location. Working Width Working Width establishes the desired distance between each adjacent pass while spreading. • To select the Working Width, use the number pad or slide bar. Fast Empty Bed RPM Fast Empty Bed RPM establishes the revolutions per minute of the roller used to drive the conveyor during the Fast Empty.
ISOBUS Job Computer : IC18 Spreader NA Calibrations Calibrations establishes either manual or automatic settings of the sensors. NOTE: For specific calibration options to appear, a specific sensor needs to be installed. Sensor availability is activated on the Sensor Presence screen in the OEM section. Figure 3-20: Calibrations Pulses Per Volume OVERVIEW Pulses Per Volume establishes number of pulses for one (1) cubic foot or one (1) cubic centimeter.
ISOBUS Job Computer : IC18 Spreader NA Implement Speed Sensor The Implement Speed Sensor establishes the wheel pulses over a specified distance. This value can be established manually or calibrated automatically. Figure 3-23: Calibrations Manual Calibration Manual calibration establishes the pulses based on a user entered value. • To select the Pulses per Distance, use the number pad or slide bar.
ISOBUS Job Computer : IC18 Spreader NA Alarm Configurations Alarm Configurations establishes alarms on or off as well Figure 3-25: Alarm Configurations as sets their trigger level. Amount Remaining Alarm On/Off The Amount Remaining Alarm will appear if the hopper amount has reached the low limit level entered. Select either “On” to activate the alarm, or “Off” to deactivate the alarm.
ISOBUS Job Computer : IC18 Spreader NA 98-05173 R1 US 27 GETTING STARTED SETUP OPERATION APPENDIX The OEM setup menu is password protected and the settings in this menu are directly related to the fitted OEM equipment. To obtain an access code, contact your local dealer or TeeJet Technologies Customer Service. To access the OEM screens: Figure 3-26: Machine to OEM 1. From the Main Setup Screen , select MACHINE. 2. Select OEM. 3. Select the Access Code Entry Box to the right of the menu option. 4.
ISOBUS Job Computer : IC18 Spreader NA ►Reference Gate Height – used to establish the actual gate height used during the calibration process ►Delete Total Counters – used to clear the Total Count system counter for Area, Volume and Time NOTE: Settings are NOT automatically saved when selected. The ACCEPT KEY must be selected to save the setting. Select the ESCAPE KEY to escape without saving settings and return to the previous menu.
ISOBUS Job Computer : IC18 Spreader NA COMMUNICATION Communication establishes the IC18's ability to communicate with an external computer. MAIN SETUP MODE MENU STRUCTURE | Communication | Help OVERVIEW Figure 3-29: Communication GETTING STARTED , | User Interface SETUP 1. From the Main Setup Screen select COMMUNICATION.
ISOBUS Job Computer : IC18 Spreader NA HELP The Help menu allows the operator to choose between Diagnostics and the display of information about serial number, CAN BUS information, etc. These menus are typically accessed upon Customer Service personnel request only. | Counters MAIN SETUP MODE MENU STRUCTURE | Job Parameters | Machine | User Interface | Communication | Help Diagnostic About 1. From the Main Setup Screen , select HELP. 2.
ISOBUS Job Computer : IC18 Spreader NA Diagnostic Figure 3-31: Diagnostic Diagnostic is used to troubleshoot input/output of the controller (sensor or actuator). ►Test Input – displays the input high and low values on the installed sensors. ►Test Output – allows the regulation valve to be tested at different percentages of dutycycle.. ►VT – provides information regarding the virtual terminal controller. ►TECU – provides information regarding the TECU.
ISOBUS Job Computer : IC18 Spreader NA VT Data Figure 3-34: VT Data The Virtual Terminal (VT) menu provides information regarding the virtual terminal controller (i.e., address version, etc.). • If more terminals/controllers are used, switch between these by pressing the GO TO NEXT VT KEY . • Press the DELETE OBJECT POOL KEY to force the VT to delete saved data and upload new information from the IC18 Job Computer on the next power cycle.
ISOBUS Job Computer : IC18 Spreader NA CHAPTER 4 – OPERATION MODE The Operation Screen accesses the working aspects of the IC18 including boom section control, rate control and trip/count/application information. NOTE: Settings are automatically saved when selected. NOTE: The menu structure on your display might vary from the one displayed in this User Manual depending on the virtual terminal being used.
ISOBUS Job Computer : IC18 Spreader NA Keys Descriptions Icon Description Home Key Press to return to the Home Screen Information Key Press to toggle between display modes Start/Stop Key Press to start or stop spreader Section and Icon Descriptions Section or Icon Description Job Information This information bar displays the active count number, applied volume and applied area Cnt OVERVIEW Count Number Displays the current active trip or job number Applied Amount Displays amount applied for t
ISOBUS Job Computer : IC18 Spreader NA Master Screen The Master Screen gives access to the systems currently available on your VT. • To view the Master Screen options, select MASTER SCREEN KEY in bottom right corner of any screen. Figure 4-2: Master Screen Master Screen Key on Operation Mode Screen Cnt 1 298.2 ton 0.0 1.14 ac 500 lb/mi lb/ac 1 3 11 Spnr 0 RPM 0 Home Screen The Home Screen gives access to the IC18’s available functions: Operation Mode, Transport Mode and Main Setup.
ISOBUS Job Computer : IC18 Spreader NA START/STOP APPLICATION Starting/stopping application is controlled using the Start/Stop Keys. Figure 4-4: Spraying Stopped • To start or stop the application, press the START/ Cnt 1 298.2 ton 1.14 STOP KEYS . 0.0 ac 500 lb/mi lb/ac 1 3 11 Rolr Spnr RPM 0 0 RPM Figure 4-5: Spraying Started Cnt 1 298.2 ton OVERVIEW 0.0 1.14 ac 500 lb/mi lb/ac 1256 GETTING STARTED Rolr RPM SETUP OPERATION APPENDIX 36 www.teejet.
ISOBUS Job Computer : IC18 Spreader NA INFORMATION KEY Information Key toggles the Speed/Application Information section on the Operation Screen between the display modes. • Vehicle speed • Volume applied per minute • Target Roller RPM Figure 4-6: Information Key Cnt 1 298.2 ton 1.14 ac 0.0 Vehicle speed 500 mph lb/ac 1 3 11 298.2 ton 1.14 ac 0.0 S pi n r lb/m RPM 0 Cnt 1 Ta r g e t Target Roller RPM RPM 500 lb/ac 0 RRoP lr M 1.
ISOBUS Job Computer : IC18 Spreader NA TRANSPORT MODE While in Transport Mode, all operation functions are locked off and cannot be activated. Transport Mode displays the speed in analogue mode. Figure 4-7: Transport Mode Home Key ►Gives access to the IC18’s available functions: Operation Mode, Transport Mode and Main Setup Speedometer Master Screen Key ►Gives access to the systems currently available on your VT OVERVIEW GETTING STARTED SETUP OPERATION APPENDIX 38 www.teejet.
ISOBUS Job Computer : IC18 Spreader NA APPENDIX A - FACTORY SETTINGS & RANGES JOB PARAMETERS Description Factory Setting Range/Options User Setting Active Trip Counter 1 1 - 10 1 2 3 4 5 6 7 8 9 0.0 lb/ac 0.0 kg/ha 0.0 - 9999 lb/ac 0.0 - 9999 kg/ha Tonnage Off Off On Gate Height 4.0 in 10.0 cm 0.0 - 35.0 in 0.0 - 99.9 cm Density 0 lb/ft3 0.00 kg/l 0 - 300 lb/ft3 0.00 - 5.
ISOBUS Job Computer : IC18 Spreader NA Operation Description Factory Setting Range/Options Speed Source CAN CAN Implement Simulated Simulated Speed 0.0 mile/h 0.0 km/h 0.0 - 99.9 mile/h 0.0 - 99.9 km/h Description Factory Setting Range/Options Working Width 40.0 ft 12.2 m 0.0 - 290.0 ft 0.0 - 90.0 m Fast Empty Bed RPM 50 RPM 0 - 9999 RPM Master Switch Console Remote Console Description Factory Setting Range Pulses per Volume 0.0 /ft3 0.0 /cm3 0.0 - 5000 /ft3 0.0 - 1500.
ISOBUS Job Computer : IC18 Spreader NA Alarm Configurations Description Factory Setting Range/Options Amount Remaining Alarm On/Off Off On Off Amount Remaining Trigger Level 0 lb 0 kg 0 - 9000 lb 0 - 4500 kg CAN Speed Source Timeout 4 sec 0 - 999 sec Active Trip Count Information Off On Off Spinner RPM Alarm On/Off Off On Off Spinner RPM Trigger Level 0 RPM 0 - 9999 RPM Description Factory Setting Options Use Perferred VT Off Off On User Setting USER INTERFACE GETTING STARTED O
I C18 S P R E A D E R J O B CO M P U T E R U S E R M A N U A L Software Version 1.05 North America, Volume Based 1801 Business Park Drive Springfield, Illinois 62703 USA Tel: (217) 747-0235 • Fax: (217) 753-8426 www.teejet.