LEADING THE CABLES FROM THE WALKER PADS
There must be a loop in the cable between the walker and the machine side as
shown on the following diagram. This loop must be large enough to "capture" the
circular movement of the straw walkers, without affecting the cable too much
(pull/push) when fixing the cable:
Do as follows to determine a suitable loop size:
1. Attach the cable on the underside of the walker approx. 20 cm from the
point at which the cable comes through the walker, as shown hereunder. Be
careful when attaching the cable fastener as this is important for the life of
the cable (see diagram):
20 cm