User Manual Owner manual

38
www.teejet.com
HOMEOVERVIEW SETUP POWER APPENDIXFULL SCREENINTRODUCTION GUIDANCE
#
Number of Boom Sections
Number of Boom Sections establishes the number of available
boom sections. If a SmartCable or Section Driver Module (SDM)
is present, 1 to 6 or 1 to 15 section widths can be entered
(depending on which SmartCable or Section Driver Module (SDM)
is detected).
1. Press DOWN arrow to access the list of options.
2. Select the number of boom sections on the implement:
Figure 6-13: Number of Boom Sections
Cong->Implement
Num Sections
Spray Width
Guidance Width
75.00 ft
75.00 ft
15
7
8
9
10
11
12
13
14
15
Guidance Width
Guidance Width establishes the width between the guidelines.
Range is 1.0 - 75.0 metres.
NOTE: This setting is required for auto steering operation.
1. Press the KEYPAD icon .
2. Use the entry screen to establish the guidance width.
Figure 6-14: Guidance Width
Cong->Implement
Num Sections
Spray Width
Guidance Width
20.00 m
21.00 m
15
Guidance Width (m)
1 2 3
20.00
Clear
4 5 6 <--
7 8 9
0 .
+/-
Spray Width
Spray width establishes the width of each implement section.
When facing forward, boom sections are ordered from left to right
along the boom. Spray width range is 1.0 - 75.0 metres. Boom
section width range is 0.0 - 75.0 metres.
NOTE: When entering a boom section width, the total of all
sections must be greater than 1.0 meter.
1. Press the KEYPAD icon .
2. Highlight the section to be established.
3. Press the KEYPAD icon .
4. Use the entry screen to establish the spray width.
5. Repeat steps 2 to 4 until all sections have been established.
NOTE: Individual boom sections can be set to different widths.
Figure 6-15: Spray Width
Cong->Implement
Num Sections
Spray Width
Guidance Width
20.00 m
180.00 ft
15
Config->Implement->Section Widths
Spray Width: 21.00 m
Section 1 - 1.40 m
Section 2 - 1.40 m
Section 3 - 1.40 m
Section 4 - 1.40 m
Section 5 - 1.40 m
Section 6 - 1.40 m
Section 7 - 1.40 m
Section 1 Width (in)
1 2 3
1.40
Clear
4 5 6 <--
7 8 9
0 .
+/-