Overlap
Overlap determines the amount of overlap allowed when each
boom section is turned on and off using Automatic Boom Section
Control.
1. Press DOWN arrow to access the list of options.
2. Select:
►0%
►50%
►100%
Figure 6-16: Overlap
Cong->Implement (2)
Overlap
Delay O
Delay On
1.00 s
1.00 s
50%
0%
50%
100%
100%
50%
0%
Delay On
Delay On functions as a “look ahead” for establishing the timing
for the boom section valves to switch on exactly when entering
an area that has not been applied. If the boom turns on too soon
when entering a non-applied area, decrease the Delay On setting.
If the boom turns on too late when entering a non-applied area,
increase the Delay On setting. Range is 0.0 - 10.0 seconds.
1. Press the KEYPAD icon .
2. Use the entry screen to establish the delay on time.
Figure 6-17: Delay On
Cong->Implement (2)
Overlap
Delay O
Delay On
1.00 s
1.00 s
50%
Delay On Time (s)
1 2 3
1.00
Clear
4 5 6 <--
7 8 9
0 .
+/-
Delay Off
Delay Off functions as a “look ahead” for establishing the timing
for the boom section valves to switch off exactly when entering an
area that has been applied. If the boom turns off too soon when
entering an applied area, decrease the Delay Off setting. If the
boom turns off too late when entering an applied area, increase
the Delay Off setting. Range is 0.0 - 10.0 seconds.
1. Press the KEYPAD icon .
2. Use the entry screen to establish the delay off time.
Figure 6-18: Delay Off
Cong->Implement (2)
Overlap
Delay O
Delay On
1.00 s
1.00 s
50%
Delay O Time (s)
1 2 3
1.00
Clear
4 5 6 <--
7 8 9
0 .
+/-