Owner manual

999-1511
TASC 6200/6500
M-T 96162
6
TASC 6500 ON LORAL AIR MAX WITH THE WET BOOM OPTION, ONE INJECTION PUMP AND TWO
GRANULAR COAPPLICATOR BINS ON THE CONVEYOR.
TASC 6500 SYSTEM DIAGRAM
BATTERY
+-
INJECTION
PUMP
100-0042
3
1
TASC 6500
114-0005
123FAN
BIN CLUTCHES
1
2
GRANULAR SWITCH BOX
105-0015
BOOM INTERFACE
CHANNEL C
CHANNEL L
FAN SENSOR
LC
DISCONNECT POINT IN
AG-CHEM AIR CYL BOX,
OR FRONT OF AIR-MAX
BED
602-0014
404-0049
602-0014
602-0014
602-0014
401-0009
401-0010
DISCONNECT POINT IN
AG-CHEM AIR CYL BOX,
OR FRONT OF AIR-MAX
BED
FAN
321
POWER
C
L
BOOM
LC
404-0048
404-0055
404-0047
AIR CLUTCH
SWITCHED
+12 VDC
GROUND
LEFT
BOOM
RIGHT
BOOM
402-0030
402-0031
120-0101 FLOW METER
405-0056
WET BOOM
VALVE
CONVEYOR
RATE SENSR
CONVEYOR
VALVE
120-0021 SENSOR
INCLUDES CABLE
404-0003
HOPPER LEVEL/FLOW
MONITOR 105-0007
404-0003
404-0003
RED (WHITE)
+12 VDC
BLACK
GROUND
3 amp
ON
OFF
123 4
602-0014
602-0014
405-0066
DJ HOPPER LEVEL
SENSOR
A
A
A
A
NOTE: Shaded areas marked "A"
denote accessories which LORAL
procures from another supplier.
A
GROUND
SPEED
A
RADAR
401-0008
Or: KIT 500-0042,
Piston Pump Drive
REMOTE MASTER SWITCH
CONNECTION
A RED, +12 VDC
B BLACK, Open
BULLETIN # 999-1214
NOTE: 602-0014 required for
AG-CHEM chassis only. Not installed
on LORAL chassis.
NOTE: 602-0014 required for
AG-CHEM chassis only. Not
installed on LORAL chassis.
BIN SENSOR
120-0008
M
BIN MOTOR
A
105-0104
Bin
Driver
M
BIN MOTOR
A
105-0104
Bin
Driver
BIN SENSOR
120-0008