Owner manual

95159
TASC 6200/6500
2-2
999-1511
DISPLAY SELECTOR FUNCTIONS IN THE
OPERATE MODE
DISPLAY SELECTOR FUNCTIONS IN THE
SET-UP MODE
Speed
Area
L & Chemicals
Vol. Appl.
L & Chemicals
Appl. Rate
L & Chemicals
% Rate
Carrier
Appl. Rate
Carrier
Vol. Applied
Width
Distance
Fan RPM
Test
Speed
Scan
The current vehicle speed in MPH
The minimum speed for the GSO function. INC/DEC switch changes.**
Accumulated area in hundreths of an acre (999.99 Maximum)*
Accumulated area in tenths of an acre (9999.9 Maximum) *
The amount of material actually discharged by channels 1,2,3 and L.
Units are not displayed. The display cycles through each position in
sequence unless a specific applicator is turned on. *
Calibration numbers for applicator positions 1,2,3 and L.
Err will
be displayed until an applicator position is selected. When channel is
non-peristaltic, density is displayed. When applicator is in split drive, all
booms must be on to view calibration number. INC/DEC changes.**
The target application rates (per acre) for channels 1,2,3. The dis-
play cycles through the active postions. INC/DEC changes by %. ***
The amount per acre to be applied by channels 1,2,3 and L. Each chan-
nel must be selected to ON and Alt-RATE in sequence. Two rates are
programable for each channel.
Err means incorrect switch setting. **
The percent of programmed rate at which all five channels are operating.
INC/DEC changes by a pre-set percentage. Alarm beeps and flashes in-
dicating abnormal operation. Switching display selector cancels. ***
The percent of change in application rate caused by each actuation of
the INC/DEC switch when in the operate mode. INC/DEC changes. **
The actual application rate by the conveyor while the vehicle is applying.
Shows the programmed rate while vehicle is at rest. INC/DEC changes
by a percentage. ***
The desired application rate for the Channel C. Two rates are program-
mable, the standard and the alternate rates. Channel switch (C) must
be on to set. INC/DEC changes. Product Density, C OFF**
The accumulated amount discharged by the conveyor. Reads pounds to
20,000 then shifts to hundredths of tons. *
The channel C/product calibration number. Calibrations should be ver-
ified for any change in density, flowability, gate setting, etc. INC/DEC
changes. **
The active boom width in feet. Depends on the actual boom sections
turned on.
Individual boom section programmed widths (inches). Display cycles
through all sections unless one is turned on. Boom section C is test
boom width. INC/DEC changes. **
Accumulated distance, miles after 5280. *
The distance calibration number. **
If no applicators are selected the display indicates the pulses per rev of the
fan sensor. INC/DEC changes. **
The speed the console will use for stationary tests of the system. When
this switch sequence is selected, booms and applicators on, the system
will apply as if it were traveling at this speed. INC/DEC changes. **
The current test speed. INC/DEC changes. **
The display will scan operational functions, holding for about two
seconds at each position.
Err , invalid switch setting.
SWITCH
SETTING
Fan RPM.
NOTES: * Totals can be zeroed in this mode. ** Values are programmable in this mode.
*** Values changeable by a % increase or decrease.
DISPLAY SELECTOR SWITCH POSITION TABLE