2D Barcode Reader User Guide V 1.2.
Table of Contents 1 Getting Started ..................................................................................................................................................................... 3 1.1 About This Guide ....................................................................................................................................................................................3 1.2 Barcode Scanning ...................................................................................
5.2.1 Code 128 ......................................................................................................................................................................................... 22 5.2.2 EAN-8................................................................................................................................................................................................ 23 5.2.3 EAN-13 ........................................................................................
1 Getting Started 1.1 About This Guide This guide provides programming instructions for the TEEMI 2D Barcoder Reader. Users can configure the TEEMI 2D Barcoder Reader by scanning the programming barcodes included in this manual. 1.2 Barcode Scanning Powered by area-imaging technology and TEEMI 2D Barcoder Reader patented “Hercules” technology, the TEEMI 2D Barcoder Reader features fast scanning and decoding accuracy. Barcodes rotated at any angle can still be read with ease.
2 Communication Interfaces The TEEMI 2D Barcoder Reader provides a TTL-232 interface and a USB interface to communicate with the host device. The host device can receive scanned data and send commands to control the engine or to access/alter the configuration information of the engine via the TTL-232 or USB interface. 2.1 TTL-232 Cable Select (Applicable to 3110) Before using Serial Communication interface, scanner must be set as TTL-232 cable. 232 Cable 2.
2.3 Baud Rate Baud rate is the number of bits of data transmitted per second. Set the baud rate to match the Host requirements.
2.4 Data Bit & Parity Check & Stop Bit Note: some products only allows default configuration (None Parity/8 Data Bits/1 Stop Bit), configuration command: 0607032; If products do not support multiple configurations, scanning the bar code of non-default configuration would error beep.
2.5 USB Interface (Applicable to 3110) Before using USB Communication interface, scanner must be set as USB cable. USB Cable 2.6 USB HID-KB When you connect the engine to the Host via a USB connection, you can enable the USB H ID -KB feature by scanning the barcode below. Then engine’s transmission will be simulated as USB keyboard input. The Host receives keystrokes on the virtual keyboard. It works on a Plug and Play basis and no driver is required.
2.7 USB Country Keyboard Types Keyboard layouts vary from country to country. The default setting is 1-U.S. keyboard. 1 – U.S.
– Belgium 11 – Bosnia 12 – Brazil 13 – Croatia 14 – Czech 15 – Dutch 16 – Estonia 17 – Germany 18 – Greek 19 – Hungary 9
20 – Irish 21 – Latvia 22 – Lithuania 23 – Macedonia 24 – Spain 25 – Poland 26 – Portugal 27 – Romania 28 – Russia 29 – Japan 10
2.8 Convert Case Scan the appropriate barcode below to convert barcode data to your desired case. No Case Conversion (Default) Convert All To Upper Case Convert All To Lower Case Exam ple: When the Convert All to Lower Case feature is enabled, barcode data “AbC” is transmitted as “abc”. 2.9 USB COM Port Emulation If you connect the engine to the Host via a USB connection, the USB C OM Port Emulation feature allows the Host to receive data in the way as a serial port does.
3 General Configuration 3.1 Trigger Mode If the Trigger Mode is enabled, you could activate the scanner by providing an external hardware trigger, or using a serial trigger command. When in manual trigger mode, the scanner scans until a barcode is read, or until the hardware trigger is released. When in serial mode, the scanner scans until a barcode has been read or until the deactivate command is sent.
3.2 Presentation Mode (Applicable to T22/TMSL50/TMSL-55/TMSL-60/TMSL-70) This set the scanner to work in presentation mode. Presentation Mode – Normal Presentation Mode - Cellphone Presentation Mode – Continue Scan 3.
3.4 Illumination Manual Trigger Mode Illumination setting for TMSL-60/TMSL-70 series. High Level Illumination (Default) Middle Level Illumination Low Level Illumination Illumination OFF Manual Trigger Mode Illumination setting for T22/TMSL-50/TMSL-55 series.
3.5 Good Read Beeper ON (Default) OFF 3.6 Good Read Beeper Volume Low Middle High (Default) 3.
3.8 Good Read Beeper Tone Low Frequency Medium Frequency (Default) Medium High Frequency High Frequency 3.
3.
4 Data Formatting 4.
4.2 Add Prefix Set Custom Prefix Save Not Save To set a customer prefix, scan the Set Custom Prefix barcode and the numeric barcodes which representing the hexadecimal values of a desired prefix, and then scan the Save barcode. Refer to Appendix 2: ASCII Table for hexadecimal values of characters. Example: Set the custom Prefix to “ODE” 1. Check the hex values of “ODE” in the ASCII Table. (“ODE”: 4F, 44, 45) 2. Scan the Set C ustom Prefix barcode. 3.
4.3 Add Suffix Set Custom Suffix Save Not Save To set a customer suffix, scan the Set Custom Suffix barcode and the numeric barcodes which representing the hexadecimal values of a desired suffix, and then scan the Save barcode. Refer to Appendix 2: ASCII Table for hexadecimal values of characters. Example: Set the custom Suffix to “ODE” 1. Check the hex values of “ODE” in the ASCII Table. (“ODE”: 4F, 44, 45) 2. Scan the Set Custom Suffix barcode. 3.
5 Symbologies 5.1 General Setting 5.1.1 Restore Symbology Default Setting Symbologies Enable: Code 128, Code 39, UPC, EAN, Interleaved 2 of 5, Code 93, Coda Bar, GS1-128, DataMatrix, PDF417, QR, Maxi Restore Symbology Default Code, Aztec. 5.1.2 Optimize Performance for Retail Use Case Make for optimize scan performance in most retail barcode scan use case. Symbologies Enable: UPC, EAN, Code128, QR, PDF417. Only Enable Retail Barcode 5.1.
5.2 1D Symbologies 5.2.1 Code 128 Enable/Disable Code 128 Enable Code 128 (Default) Disable Code 128 Message Length Message length can be set to the maximum value or minimum value. The value between the maximum and the minimum is valid. The maximum value and minimum value can be set using “Programming Command”. Please check the programming command guide for the detail. Code 128 max length command: 020A03. The parameter of this command can be set from min to 90. Code 128 min length command: 020A02.
5.2.2 EAN-8 Enable/Disable EAN-8 Enable EAN-8 (Default) Disable EAN-8 Transmit Check Digit EAN-8 is 8 digits in length with the last one as its check digit used to verify the accuracy of the data. Transmit EAN-8 Check Digit (Default) Do Not Transmit EAN-8 Check Digit Add-On Code An EAN-8 barcode can be augmented with a two-digit or five-digit add-on code to form a new one.
Enable 2-Digit Add-On Code Disable 2-Digit Add-On Code (Default) Enable 5-Digit Add-On Code Disable 5-Digit Add-On Code (Default) Add-On Code Required EAN-8 Add-On Code Required EAN-8 Add-On Code Not Required (Default) ENA/JAN-8 Addenda Separator When this feature is enabled, there is a space between barcode and addenda. When this feature is disabled, there is no space.
5.2.
Add-On Code Required EAN-13 Add-On Code Required EAN-13 Add-On Code Not Required (Default) ENA/JAN-13 Addenda Separator When this feature is enabled, there is a space between barcode and addenda. When this feature is disabled, there is no space. Enable ENA/JAN-13 Addenda Separator (Default) Disable ENA/JAN-13 Addenda Separator ISBN Translate When enable this feature and is scanned, ENA-13 Book land symbols are translated into their equivalent ISBN number format.
5.2.
UPC-E0 Expand UPC-E0 expand expands the UPC-E code to the 12 digits, UPC-A format. Enable UPC-E0 Expand Disable UPC-E0 Expand (Default) UPC-E0 Addenda Required When required is scanned, the scanner will only read UPC-E barcodes that have addenda.
UPC-E0 Number System The number system digit of UPC symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will be not transmitted.
5.2.5 UPC-A Enable/Disable UPC-A Enable UPC-A (Default) Disable UPC-A UPC-A Check Digit Enable UPC-A Check Digit (Default) Disable UPC-A Check Digit UPC-A Addenda Required When required is scanned, the scanner will only read UPC-E barcodes that have addenda.
UPC-A Addenda Separator Enable UPC-A Separator (Default) Disable UPC-A Separator UPC-A: Number System The number system digit of UPC symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will be not transmitted.
UPC-A: Addenda Enable 2 Digit Addenda Disable 2 Digit Addenda (Default) Enable 5 Digit Addenda Disable 5 Digit (Default) 32
5.2.6 Interleaved 2 Of 5 Enable/Disable Interleaved 2 Of 5 Enable Interleaved 2 Of 5 (Default) Disable Interleaved 2 Of 5 Message Length Message length can be set to the maximum value, minimum value. The data between the maximum and the minimum is valid. The maximum value and minimum value can be set using Programming Command. Please check the programming command guide for the detail. Interleaved 2 of 5 max length command: 020404. The parameter of this command can be set from min to 80.
5.2.7 Matrix 2 Of 5 Enable/Disable Matrix 2 Of 5 Enable Matrix 2 Of 5 Disable Matrix 2 Of 5 (Default) Message Length Message length can be set to the maximum value, minimum value. The value is valid between the maximum and the minimum. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail. Matrix 2 of 5 max length command: 020803. The parameter of this command can be set from min to 80. Matrix 2 of 5 min length command: 020802.
5.2.8 Industrial 2 Of 5 Enable/Disable Industrial 2 Of 5 Enable Industrial 2 Of 5 Disable Industrial 2 Of 5 (Default) Message Length Message length can be set to the maximum value, minimum value. The value is valid between the maximum and the minimum. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail. Industrial 2 of 5 max length command: 020603. The parameter of this command can be set from min to 48.
5.2.
Code 39 Append This function allows the scanner to append several Code 39 barcode data together before transmitting to host. When the scanner encounters a Code 39 barcode with append character (ex. Space character), it buffers the data until it reads a Code 39 barcode which does not have append character. Then the data is transmitted in the order that the barcodes were read.
5.2.10 Coda Bar Enable/Disable Coda Bar Enable Coda Bar (Default) Disable Coda Bar Message Length Message length can be set to the maximum value, minimum value. The data between the maximum and the minimum is valid. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail. Coda bar max length command: 020206. The parameter of this command can be set from min to 60. Coda bar min length command: 020205.
Transmit Start/Stop Character Transmit Start/Stop Character Do Not Transmit Start/Stop Character (Default) Coda bar Check Character No Check Char (Default) Validate And Transmit Validate No Transmit 39
5.2.11 Code 93 Enable/Disable Code 93 Enable Code 93 (Default) Disable Code 93 Message Length Message length can be set to the maximum value, minimum value. The data between the maximum and the minimum is valid. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail. Code 93 max length command: 020D03. The parameter of this command can be set from min to 80. Code 93 min length command: 020D02.
5.2.12 GS1-128 Enable/Disable GS1-128 Enable GS1-128 (Default) Disable GS1-128 Message Length Message length can be set to the maximum value, minimum value. The data between the maximum and the minimum is valid. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail. GS1-128 max length command: 020B03. The parameter of this command can be set from min to 80. GS1-128 min length command: 020B02.
5.2.13 MSI Enable/Disable MSI Enable MSI Disable MSI (Default) Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail. MSI max length command: 020E04. The parameter of this command can be set from min to 48. MSI min length command: 020E03. The parameter of this command can be set from 4 to max.
MSI Check Character Validate Type10 Transmit Validate 2 Type10 No Transmit (Default) Validate Type10 Then Type11 Char NO Transmit Validate Type10 Then Type11 Char Transmit Validate 2 Type10 Char Transmit Validate 2 Type10 Char No Transmit Disable MSI Check 43
5.2.
5.3 2D Symbologies 5.3.1 PDF 417 Enable/Disable PDF 417 Enable PDF 417 (Default) Disable PDF 417 Enable/Disable Micro PDF 417 Enable Micro PDF 417 Disable Micro PDF 417 (Default) Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail. PDF417 max length command: 021F06.
5.3.2 QR Code Enable/Disable QR Code Enable QR Code (Default) Disable QR Code Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum is valid. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail. QR max length command: 023703. The parameter of this command can be set from min to 7089. QR min length command: 023702.
5.3.3 Data Matrix Enable/Disable Data Matrix Enable Data Matrix (Default) Disable Data Matrix Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail. Data Matrix max length command: 023603. The parameter of this command can be set from min to 3116. Data Matrix min length command: 023602.
5.3.4 Maxi code Enable/Disable Maxi code Enable Maxi Code Disable Maxi Code (Default) Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail. Maxi Code max length command: 023403. The parameter of this command can be set from min to 150. Maxi Code min length command: 023402.
5.3.5 Aztec Enable/Disable Aztec Enable Aztec (Default) Disable Aztec Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail. Aztec max length command: 023306. The parameter of this command can be set from min to 3832. Aztec min length command: 023305.
5.3.6 Hanxin Enable/Disable Hanxin Enable Hanxin Disable Hanxin (Default) Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail. Hanxin max length command: 023803. The parameter of this command can be set from min to 7833. Hanxin min length command: 023802.
5.4 Postal Symbologies 5.4.1 China Postal Code Enable/Disable China Postal Code Enable China Postal Code Disable China Postal Code (Default) 5.4.
6 Appendix 6.
]F0 Standard Codebar ]F2 Transmit check digit after parity check ]F4 Do not transmit check digit after parity check ]G0 Standard Code 93 ]H0 One check digit MOD11; transmit check digit ]H1 Two check digits, MOD11/MOD11; transmit check digit ]H3 Do not transmit check digit after parity check ]H9 No parity check GS1-DataBar (RSS) ]e0 Standard GS1-DataBar Plessey ]P0 Standard Plessey ]M0 One check digit, MOD10; transmit check digit ]M1 One check digit, MOD10; do not transmit check digi
]Q5 ]Q6 QR Code 2005,ECI excluded,FNC1 is the 2nd character after the start character QR Code 2005, ECI included, FNC1 is the 2nd character after the start character Referen ce : ISO/IEC 15424:2008 Information technology – Automatic identification and data capture techniques – Data Carrier Identifiers (including Symbology Identifiers).
6.2 Appendix 2: ASCII Table Hex Dec Char 00 0 NUL (Null char.
Hex Dec Char 22 34 " (Double Quote) 23 35 # (Number Sign) 24 36 $ (Dollar Sign) 25 37 % (Percent) 26 38 & (Ampersand) 27 39 ` (Single Quote) 28 40 ( (Right / Closing Parenthesis) 29 41 ) (Right / Closing Parenthesis) 2a 42 * (Asterisk) 2b 43 + (Plus) 2c 44 , (Comma) 2d 45 - (Minus / Dash) 2e 46 .
Hex Dec Char 46 70 F 47 71 G 48 72 H 49 73 I 4a 74 J 4b 75 K 4c 76 L 4d 77 M 4e 78 N 4f 79 O 50 80 P 51 81 Q 52 82 R 53 83 S 54 84 T 55 85 U 56 86 V 57 87 W 58 88 X 59 89 Y 5a 90 Z 5b 91 [ (Left / Opening Bracket) 5c 92 \ (Back Slash) 5d 93 ] (Right / Closing Bracket) 5e 94 ^ (Caret / Circumflex) 5f 95 _ (Underscore) 60 96 ' (Grave Accent) 61 97 a 62 98 b 63 99 c 64 100 d 65 101 e 66 102 f 67 103 g
Hex Dec Char 6a 106 j 6b 107 k 6c 108 l 6d 109 m 6e 110 n 6f 111 o 70 112 p 71 113 q 72 114 r 73 115 s 74 116 t 75 117 u 76 118 v 77 119 w 78 120 x 79 121 y 7a 122 z 7b 123 { (Left/ Opening Brace) 7c 124 | (Vertical Bar) 7d 125 } (Right/Closing Brace) 7e 126 ~ (Tilde) 7f 127 DEL (Delete) 58
6.