User's Manual

GB
9
adjusted. To do this, light the burners and
check that they do not go out if you switch
quickly from the maximum to the minimum.
Before connecting the hob to the electric
mains, check that the voltage and fre-
quency of the mains matches that shown
on the hobs rating plate, which is located
lower down, and on the guarantee certifi-
cate or, where appropriate, the technical
datasheet supplied, which should be kept
together with this manual.
The connection is made via an omnipolar
switch or plug where accessible, which is
suitable for the intensity to be tolerated
and which has a minimum gap of 3 mm
between its contacts, which will ensure
disconnection in case of emergency or
when cleaning the hob.
The connection should include correct ear-
thing, in compliance with current norms.
If the flexible supply cable fitted to these
appliances ever needs to be changed, it
should be replaced by TEKAs official SAT
cable, which requires special tools.
The input cable should not be in contact
either with the body of the hob or with the
body of the oven, if the oven is installed in
the same unit.
Important!
Any alteration that is to be made to the
appliance to convert it to a different
type of gas should only be carried out
by an authorised person and should
comply with current standards.
Information for Technical Assis-
tance: whenever the type of gas or the
appliances pressure is changed, the new
regulation plate should be placed on top of
the old one so that the new features can
be seen after the change.
The tasks involved in conversion are:
* Replace the injectors.
* Adjust the taps minimums.
The injectors required for each gas type
are shown in table 1.
To replace the injectors, follow these ins-
tructions:
1 Remove the grids and upper parts of the
burner so that the injector can be seen.
2 Using a number 7 pipe spanner, remove
the injectors and replace them with the
new ones. Ensure that the injector is
properly tightened and so avoid gas
escaping.
3 Replace the grid and burners that were
previously removed.
When the injectors have been changed,
adjust the minimums as follows:
1 Turn the burners on to their minimum.
Connecting the electricity